300 KVA Òkú Front Ayirapada-12.47 / 0.208 KV|Canada 2024

300 KVA Òkú Front Ayirapada-12.47 / 0.208 KV|Canada 2024

Orilẹ-ede Ifijiṣẹ: Canada 2024
Agbara: 300kVA
Foliteji: 12.47Grdy/7.2 X 4.16Grdy/2.4-0.208y/0.12 kV
Ẹya: Pẹlu IFD
Fi ibere ranṣẹ

 

300 kva dead front transformers-inside-view

SCOTECH's 300 kVA oku{1}iwaju awọn transformers n funni ni igbẹkẹle, CSA{2}}agbara ibamu fun Canada.

 

 

01 Gbogbogbo

1.1 Project Apejuwe

Ni ọdun 2024, alabara ara ilu Kanada kan gbe aṣẹ fun awọn oluyipada iwaju KVA 300 mẹjọ ti a ṣe apẹrẹ ati iṣelọpọ ni ibamu ni kikun pẹlu CSA Standard C227.4:21. Awọn oluyipada wọnyi ni a ṣe fun ṣiṣe igbẹkẹle ni ita, loop{4}}awọn ọna ṣiṣe pinpin ifunni pẹlu awọn nẹtiwọọki ilẹ to munadoko.

300 kVA mẹta -paadi alakoso{2}} ti a gbe sori ẹrọ ni a pese gẹgẹ bi ara iṣẹ akanṣe yii. O ni apẹrẹ ti o ku- iwaju ti o ni idaniloju aabo ati ṣiṣe irọrun. Ọna itutu agbaiye jẹ ONAN, pese ifasilẹ ooru ti o gbẹkẹle labẹ gbogbo awọn ipo fifuye. Oluyipada naa nlo idabobo epo ti o wa ni erupe ile ati awọn iyipo aluminiomu, fifun ni iwontunwonsi to dara laarin ṣiṣe giga ati iye owo. O jẹ iwọn 300 kVA, 60 Hz, pẹlu foliteji akọkọ ti 12.47/4.16 kV ati foliteji keji ti 0.208 kV.

Asopọ yika jẹ YNyn0, o dara fun awọn nẹtiwọọki pinpin ilẹ. A ko - oluyipada tẹ ni kia kia (NLTC) ti pese pẹlu iwọn titẹ ± 2×2.5% kan. Eyi ngbanilaaye atunṣe foliteji irọrun lati baamu awọn ipo iṣẹ oriṣiriṣi ati rii daju iṣẹ ṣiṣe eto iduroṣinṣin. Oluyipada naa ṣaṣeyọri ṣiṣe 98.94%, laisi - awọn adanu fifuye Kere tabi dọgba si 800 W ati awọn adanu ẹru Kere tabi dọgba si 3580 W. O ni awọn ẹya ara ẹrọ CSA ti o ni ibamu ati apẹrẹ ẹsẹ marun-un fun iṣẹ iduroṣinṣin labẹ asopọ Y–Y kan.

Ifijiṣẹ yii ṣe afihanIfaramo SCOTECH si jiṣẹ didara giga-, CSA{0}}awọn transformer ti a fọwọsi ti a ṣe fun ọja pinpin agbara ti Canada.

 

 

 

1.2 Imọ pato

300 KVA okú iwaju Ayirapada sipesifikesonu ati data dì

Jišẹ si
Canada
Odun
2024
Iru
Meta alakoso paadi òke transformer
Standard
CSA C227.4:21
Ti won won Agbara
300KVA
Igbohunsafẹfẹ
60HZ
Ifunni
Radial
Iwaju
Òkú
Ipele
mẹta
Itutu agbaiye
ONAN
Insulant olomi
Epo Eruku
Primary Foliteji
12.47 (4.16) kV
Secondary Foliteji
0,208 kV
Ẹgbẹ Vector
YNyn0
Ohun elo Yiyi
Aluminiomu
Ipalara
4 %
Iṣẹ ṣiṣe
98.94%
Tẹ Ayipada
NLTC
Ibiti titẹ ni kia kia
±2*2.5%
Ko si Ipadanu Ẹru
Kere ju tabi dọgba si 800 W
Lori Ipadanu Fifuye
Kere ju tabi dọgba si 3580 W
Awọn ẹya ẹrọ
Standard iṣeto ni

 

1.3 yiya

300 KVA okú iwaju Ayirapada iyaworan ati nameplate

300 KVA Dead Front Transformers drawing 300 KVA Dead Front Transformers nameplate

 

 

02 iṣelọpọ

2.1 Epo Ipele Atọka

300 kVA dead front transformers Oil Level Indicator

Atọka ipele epo jẹ ki o rii epo 300 KVA ti o ku iwaju awọn oluyipada ni iwo kan, ni akoko gidi, nitorinaa o mọ boya o wa nibiti o yẹ ki o wa. Epo kii ṣe idabobo nikan - o gbe ooru kuro lati awọn yikaka ati koko paapaa. Ti ipele ba lọ silẹ, o le jẹ jijo, tabi nkan inu le jẹ aṣiṣe. Pẹlu awọn ifojusọna wiwo tabi awọn sensọ, awọn oniṣẹ le gbe soke tabi ṣayẹwo ni kiakia, ṣe iranlọwọ lati dena awọn ikuna ati fa igbesi aye sii. Nigbagbogbo fi sori ẹrọ nibiti o rọrun lati ṣayẹwo, o jẹ ki awọn ayewo ojoojumọ jẹ ailewu ati rọrun.

 

2.2 IFD & Sisan àtọwọdá

Oluwari Aṣiṣe Inu inu, IFD, ati àtọwọdá sisan ọkọọkan ni ipa wọn, ṣugbọn papọ wọn tọju ẹrọ iyipada lailewu. IFD ni imọlara awọn gaasi dani tabi awọn ifihan agbara arc kekere, ikilọ nipa yiyi tabi awọn ọran idabobo ni kutukutu. Atọpa sisan jẹ ki o yọ epo kuro, fun itọju deede tabi awọn pajawiri. Pẹlu awọn mejeeji, o le yẹ awọn ewu ni kutukutu ki o mu epo lailewu. Paapa ni awọn oluyipada akoko mẹta{{4}, awọn titaniji ti akoko ati mimu epo mimu ṣe iranlọwọ lati jẹ ki ohun gbogbo duro ati yago fun awọn iṣoro nla ni isalẹ laini.

300 kVA dead front transformers IFD Drain Valve

 

 

2.3 Titẹ Iderun Idena & Iwọn Ipa Ipa

300 kVA dead front transformers Pressure Relief Valve Vacuum Pressure Gauge

Ninu ẹrọ oluyipada, àtọwọdá iderun titẹ ati wiwọn titẹ igbale ṣiṣẹ bi ẹgbẹ ailewu kekere kan. Àtọwọdá ìtura{1} máa ṣí nígbà tí ìfúnpá gaasi bá ga jù; aabo fun ojò, edidi. Iwọn igbale - ṣe afihan awọn iyipada titẹ, awọn itọni si awọn iyipada iwọn otutu, imugboroosi epo, boya awọn ọran ifidipo. Papọ, wiwo iyara yoo fun awọn oniṣẹ ni aworan gbogbogbo. Aami overpressure, titẹ odi ni kutukutu; iranlọwọ fi idabobo, darí awọn ẹya ara. Paapa pataki ni awọn oluyipada alakoso{{7}, nibiti asise kan le ta gbogbo ẹyọkan.

 

2.4 Thermometer

Awọn thermometer tọpa epo ati awọn iwọn otutu yikaka, ti n fihan bi o ṣe gbona ti ẹrọ oluyipada ti nṣiṣẹ. Ooru ti o ga ju epo lọ ni iyara, n ṣe idabobo idabobo, ati pe o le ṣiṣẹ awọn windings. Wiwo awọn kika ṣe iranlọwọ fun awọn oniṣẹ pinnu boya lati dinku fifuye, ṣe afẹfẹ diẹ sii, tabi gbero itọju. Alaye naa le ṣe ayẹwo pẹlu ọwọ tabi jẹun sinu awọn eto ibojuwo. Fun awọn ipele ipele mẹta{{4}, o ṣe pataki lati rii iwọn otutu ipele kọọkan, titọju awọn nkan ni iwọntunwọnsi, yago fun awọn iyanilẹnu, ati rii daju pe agbara n tẹsiwaju ni imurasilẹ.

300 kVA dead front transformers Thermometer

 

03 Idanwo

Igbeyewo Standard  

CSA C227.4-21

Ipele{0}mẹta,paadi - awọn transformer pinpin kaakiripẹlu separable sọtọ

ga - awọn asopọ foliteji

CSA{0}C802.1-13 (R2022)

Awọn iye ṣiṣe to kere julọ fun Liquid{0}}Awọn Ayirapada Pipin Pipin

 

Idanwo baraku

1 Resistance wiwọn
2 Awọn idanwo ipin
Igbeyewo Ibasepo Alakoso 3
4 Ko si Awọn ipadanu fifuye ati Ko si fifuye lọwọlọwọ
5 Fifuye adanu Impedance Foliteji ati ṣiṣe
6 Applige Foliteji Idanwo
7 Induced Foliteji withstand Igbeyewo
8 Idanwo Leak pẹlu Ipa fun Awọn Ayirapada Immersed Liquid
9 Idiwọn Resistance Idaabobo
10 Oil Dielectric igbeyewo

300 KVA Dead Front Transformers test
300 KVA Dead Front Transformers fat test

 

04 Iṣakojọpọ ati Sowo

300 KVA Dead Front Transformers packing
300 kva dead front transformers-export-packing
300 kva dead front transformers-wooden crate packaging

 

05 Ohun elo

 

300 kVA dead front transformers application data centers
300 kVA dead front transformers application industrial manufacturer
300 kVA dead front transformers application residential community
Ọjọ Center Olupese ile-iṣẹ Agbegbe Ibugbe

 

 

Awọn afiwe Gbona: Awọn oluyipada iwaju ti o ku, olupese, olupese, idiyele, idiyele