112.5 KVA Ọpa Ti a gbe soke 3 Awọn iyipada Alakoso-13.8 / 0.208 KV|Canada 2025

112.5 KVA Ọpa Ti a gbe soke 3 Awọn iyipada Alakoso-13.8 / 0.208 KV|Canada 2025

Orilẹ-ede: Canada 2025
Agbara: 112.5 kVA
Foliteji: 13.8D-0.12 / 0.208kV
Ẹya-ara: pẹlu itọkasi ipele epo
Fi ibere ranṣẹ

Jiangshan Scotech Electrical Co., Ltd jẹ ọkan ninu awọn olupese ti o gbẹkẹle julọ ati awọn olupese ti 112.5 kva polu mounted 3 phase transformers-13.8/0.208 kv|Canada 2025 ni China. Jọwọ lero ọfẹ lati ra awọn ọja to munadoko fun tita nibi ati gba awọn aworan atọka lati ile-iṣẹ wa. Kan si wa fun alaye sii.

 

pole mounted 3 phase transformers

Iduroṣinṣin lori, Igbesi aye Agbara ni isalẹ. Gbẹkẹle polu Agesin Ayirapada.

 

 

01 Gbogbogbo

1.1 Project Apejuwe

112.5 kVA mẹta ipele opo ti o gbe transformer ti a fi jiṣẹ si Canada ni 2025. Agbara ti a ṣe ayẹwo ti transformer jẹ 112.5 kVA pẹlu itutu ONAN. Iwọn giga jẹ 13.8D kV pẹlu ± 2 * 2.5% ibiti o tẹ ni kia kia (NLTC), foliteji kekere jẹ 0.12 / 0.208 kV, wọn ṣẹda ẹgbẹ fekito ti Dyn1.

Yi 112.5kVA mẹta -pase opo - transformer ti a gbe soke jẹ - ẹrọ iyipada agbara iṣẹ ṣiṣe ni agbedemeji{4}} awọn nẹtiwọọki pinpin foliteji kekere, ti n ṣiṣẹ bi ipin pinpin bọtini fun awọn ebute nẹtiwọọki pinpin ilu, awọn ẹka ọgba iṣere, ati awọn eto ipese agbara agbegbe jijin. O gba opo kan- eto fifi sori idadoro idadoro, ni ipese pẹlu ita gbangba{7}}apatapata kan pato-ipata ati ipata{9}}ẹri ti a fi edidi minisita ati 13.8kV- awọn igbo idabobo kilasi, eyiti o dara fun imuṣiṣẹ laini oke ni giga. Iyipada ilana foliteji kan jẹ tunto lori giga rẹ - ẹgbẹ foliteji, nmu ±2*2.5% jẹ itanran foliteji{16}} lati ṣatunṣe ni irọrun si awọn iyipada akoj ati rii daju pe opin iduroṣinṣin{17}} ipese agbara olumulo.

Pẹlu agbara ti o ni iwọn 112.5kVA, o ṣe atilẹyin alabọde 13800V{2}}igbewọle foliteji ati 208V/120V kekere-jade foliteji. Labẹ awọn ipo fifuye ipele mẹta -, o le gbe isunmọ. 158Iwọn lọwọlọwọ lọwọlọwọ lori kekere-ẹgbe foliteji{10}ti o lagbara lati pese{11}Agbara ipele mẹta fun ohun elo ile-iṣẹ, lakoko ti o tun pade awọn iwulo ina ina nikan{12} fun awọn olumulo iṣowo ati ibugbe. Imudara iyipada agbara rẹ kọja 98.74% labẹ ẹru ti a ṣe iwọn, ni imunadoko pipadanu agbara ni ọna asopọ pinpin.

Oluyipada yii wulo pupọ si awọn oju iṣẹlẹ pẹlu isọdọtun nẹtiwọọki pinpin ilu (yanju awọn ọran apọju ni awọn agbegbe atijọ), pinpin ẹka ile-iṣẹ ogba ile-iṣẹ (ti o ṣe atilẹyin ipese agbara ti nlọ lọwọ fun kekere ati alabọde{0}), agbegbe ipese agbara agbegbe latọna jijin (awọn ela agbara ni igberiko ati awọn agbegbe igberiko), ati awọn oju iṣẹlẹ agbara igba diẹ (gẹgẹbi ikole ita gbangba nla ati awọn iṣẹlẹ). Ti a fiwera pẹlu awọn ẹrọ iyipada ti ilẹ-, kii ṣe fifipamọ aaye ilẹ nikan ṣugbọn o tun mu iṣẹ ṣiṣe dara si ati aabo itọju nipa jikuro si awọn agbegbe iṣẹ oṣiṣẹ. Ipele idabobo giga rẹ ati atako - oniru ibajẹ jẹ ki igbesi aye iṣẹ ita gbangba ti o ju 20 ọdun lọ, ni pataki idinku iṣẹ ṣiṣe pipẹ ati awọn idiyele itọju igba pipẹ-. Nibayi, iṣẹ ilana foliteji rẹ le dinku ipa ti awọn iyipada foliteji lori ohun elo konge, ṣiṣe ni aṣayan akọkọ fun awọn iṣagbega nẹtiwọọki pinpin pẹlu iwapọ, igbẹkẹle giga, ati isọdọtun oju iṣẹlẹ.

 

 

 

1.2 Imọ pato

112,5 kVA polu agesin transformer pato iru ati data dì

Jišẹ si
Canada
Odun
2025
Iru
Polu agesin transformer
Standard
CSA C2.2-06
Ti won won Agbara
112,5 kVA
Giga
Kere ju tabi dogba si 1000m
Igbohunsafẹfẹ
60HZ
Ipele
1
Itutu agbaiye
ONAN
Primary Foliteji
13.8D kV
Secondary Foliteji
0,208 / 0,12 kV
Ohun elo Yiyi
Aluminiomu
Ipalara
3.5%
Iṣẹ ṣiṣe
Ti o tobi ju tabi dọgba si 98.74%
Tẹ Ayipada
±2*2.5%
Ko si Ipadanu Ẹru
0,475 kW
Lori Ipadanu Fifuye
1.06 kW
Àwọ̀
ANSI Grey70#

 

1.3 Yiya

112,5 kVA polu agesin transformer aworan atọka yiya ati iwọn.

pole mounted 3 phase transformers diagram pole mounted 3 phase transformers nameplate

 

 

02 iṣelọpọ

2.1 ojò

pole mounted 3 phase transformers oil tank

Eyi ni ojò fun 112.5kVA mẹta -pase alase - transformer ti a gbe soke, ti a ṣe lati inu irin alagbara ati ni agbedemeji{3}} iṣelọpọ ti pari (pẹlu alakoko grẹy lo). O ni eto welded onigun mẹrin: oke pẹlu awọn atọkun fun awọn paati mojuto transformer, lakoko ti awọn ṣiṣii ipin 4 iwaju ti wa ni ipamọ fun awọn onirin / awọn ẹya ẹrọ. Ti a ṣe pẹlu awọn ideri ti a fi ipari si (ti a rii nitosi), yoo gbe awọn ẹya inu inu, mu epo idabobo (fun idabobo ati sisọ ooru), ati idaabobo awọn ohun elo inu lẹhin igbimọ kikun.

 

2.2 ik Apejọ

Eyi ni aaye apejọ ti o kẹhin ti 112.5kVA mẹta -polu alakoso{2}} ti a gbe sori ẹrọ transformer, pẹlu ilana alurinmorin okun waya ti nlọ lọwọ lọwọlọwọ. Ti o han nihin ni awọn paati pataki ti transformer (pẹlu awọn yiyi afẹfẹ mẹta- ti a we sinu idabobo funfun), ati pe oṣiṣẹ kan n mu awọn okun waya adari alagara ti o ya sọtọ{5}} n ṣe alurinmorin wọn lati so awọn yiyi pọ pẹlu awọn ebute ita (igbesẹ pataki lati rii daju gbigbe agbara iduroṣinṣin). Awọn irinṣẹ apejọ ti o wọpọ (bii awọn scissors ati awọn wrenches) dubulẹ nitosi; Asopọ onirin yii jẹ ọna asopọ itanna to ṣe pataki ni apejọ ikẹhin, fifi ipilẹ ipilẹ lelẹ fun tiipa apade atẹle ati idanwo iṣẹ.

pole mounted 3 phase transformers assembled

 

2.3 Titẹ Relief Device

Pressure Relief Device

Ohun elo iderun titẹ ti a fi sori ẹrọ 112.5kVA mẹta yii{1}}pase ipele- transformer ti a gbe soke jẹ paati aabo to ṣe pataki ti a ṣe apẹrẹ lati gbejade awọn gaasi ti o wa ni inu ni iṣẹlẹ ti aṣiṣe inu ti o lagbara tabi ikojọpọ titẹ pupọ. O ṣiṣẹ bi ailagbara ẹrọ kan, mu ṣiṣẹ lẹsẹkẹsẹ lati yago fun rupture ojò ajalu nipa itusilẹ titẹ nipasẹ ibudo atẹgun iyasọtọ, nitorinaa idinku eewu ina, bugbamu, ati ibajẹ ohun elo. Ni deede ifihan asia wiwo tabi atọka ti o ṣe ifihan iṣẹ ṣiṣe, ẹrọ naa ṣe iranlọwọ lati daabobo iduroṣinṣin igbekalẹ ti oluyipada ati ṣe idaniloju aabo awọn amayederun ohun elo agbegbe ati oṣiṣẹ. Ni kete ti o ti mu ṣiṣẹ, o nilo ayewo afọwọṣe ati tunto lakoko itọju atẹle.

 

2.4 Tẹ Ayipada

Oluyipada tẹ ni kia kia ni ipese lori 112.5kVA mẹta yii -pase ipele{2}} transformer ti a gbe soke jẹ boṣewa WSLⅡ3 63/20{6}}6×5 pipa{7}}Iru Circuit, ẹya ẹrọ gbogbo agbaye ti a ṣe fun epo{9}}awọn transformer ti a fi sinu omi dipo ẹyọkan aṣa. Ti fi sori ẹrọ lori giga - ẹgbẹ foliteji ti transformer, o ṣe ẹya foliteji ti o ni iwọn ti 20kV ati lọwọlọwọ oṣuwọn ti 63A, pẹlu awọn ipo titẹ ni kia kia 5 ti o jẹ ki iwọn ilana foliteji ±2×2.5% - iyọrisi atunṣe foliteji iduroṣinṣin nipa yiyipada nọmba awọn yiyi yikaka akọkọ. Gẹgẹbi paati pataki fun imuduro foliteji, o gbọdọ ṣiṣẹ nigbati a ba ti ni agbara ẹrọ iyipada{18} lati rii daju iyipada ailewu, isanpada imunadoko fun awọn iyipada foliteji grid ati mimu iṣelọpọ agbara kekere-kekere deede fun awọn olumulo ipari.

Apẹrẹ igbekalẹ to lagbara ni ibamu pẹlu ọpá ita gbangba ti transformer - iṣẹ ti a fi sori ẹrọ, ti o farada awọn ipo ayika lile lakoko ti o n ṣe idaniloju iṣẹ ṣiṣe ti o gbẹkẹle jakejado lilo igba pipẹ{{1}.

Tap Changer

 

2.5 Epo Ipele Atọka

Oil Level Indicator

Atọka ipele epo jẹ apẹrẹ UHZ {{1}01 boṣewa, ẹya ẹrọ ẹrọ gbogbo agbaye ti a ṣe apẹrẹ fun alabọde ati kekere{2}epo ti o ni iwọn{4}} awọn transformers ti a rì bọmi dipo ẹyọkan aṣa. Ti fi sori ẹrọ ni inaro ni ẹgbẹ ti olutọju epo ti oluyipada, o ṣiṣẹ da lori awọn ipilẹ ti buoyancy ati isọpọ oofa: leefofo inu inu n gbe ni iṣọkan pẹlu ipele epo idabobo, ti n ṣe afihan itagbangba lati ṣe afihan ipele omi ni kikun-rọpo awọn iwọn tube gilasi ibile pẹlu ailewu imudara, hihan, ati agbara. Ti a ṣe ẹrọ lati koju awọn ipo ita gbangba lile, o ṣe ẹya iwọn otutu iṣiṣẹ jakejado ti -40 iwọn si iwọn 80, ṣe deede si ọriniinitutu ibatan to 90% (ni iwọn 25), ati pe o ṣiṣẹ ni igbẹkẹle ni awọn giga Kere tabi dọgba si 2000m laisi ni ipa nipasẹ gbigbọn lile tabi awọn aaye oofa to lagbara. Gẹgẹbi paati ibojuwo to ṣe pataki, o ngbanilaaye awọn oṣiṣẹ itọju lati yara ṣayẹwo ipo ipele epo, ni idaniloju idabobo to ati iṣẹ ṣiṣe itusilẹ ooru ti ẹrọ oluyipada ati atilẹyin laasigbotitusita akoko lati yago fun awọn eewu iṣẹ ṣiṣe ti aito epo tabi apọju.

 

2.6 Kekere -Foliteji Bushing

Iwọn kekere {{0}foliteji bushing ti 112.5kVA mẹta -pase alakoso{3}} transformer ti a gbe soke jẹ awoṣe boṣewa 251101-12XD.401.004.B, ẹya ẹrọ gbogbo agbaye fun epo{8} awọn transformers immersed. Ti a gbe si ẹgbẹ ojò, o jẹ ti okun gilasi{9}} polyester thermoset imudara fun oju ojo to lagbara, ti o baamu ọpá ita gbangba{15}} awọn iṣẹ ṣiṣe. Ti a ṣe iwọn fun iṣẹjade 208V/120V ti transformer pẹlu Ti o tobi ju tabi dọgba si agbara lọwọlọwọ 200A (ti o kọja iwọn kekere 158A{16}}iwọn ẹgbẹ foliteji), o ni awọn ebute idẹ tin{19}} awọn ebute idẹ ti o ni igbẹkẹle fun awọn isopọ to gbẹkẹle. Ni ibamu pẹlu awọn iṣedede idabobo 1.2kV ati ni ipese pẹlu jijo{20} awọn edidi ẹri, o ntan lailewu agbara foliteji kekere lakoko aabo awọn paati inu.

Low-Voltage Bushing

 

2.7 Giga -Foliteji Bushing

High-Voltage Bushing

Giga -foliteji bushing ti 112.5kVA mẹta -pase opo - ti a fi sori ẹrọ transformer jẹ awoṣe boṣewa 12XD.401.010-A, ẹya ẹrọ gbogbo agbaye fun epo{12}}awọn transformers immersed. Ti a gbe sori ojò naa, o ṣe ẹya ara idabobo tanganran ati awọn ebute idẹ, ti wọn jẹ 18KV/55A pẹlu ijinna irako Ti o tobi ju tabi dọgba si 450.85mm ati 125KV imunana agbara ina duro foliteji, aridaju ailewu giga{13} agbara foliteji fun awọn iṣẹ ti a gbe soke si ita.

 

 

03 Idanwo

112.5kVA mẹta -ọpa ipele{2}} ti o gbe transformer (awoṣe: 112.5kVA-13.8DELTA-0.208/0.12kV) ṣe awọn idanwo igbagbogbo fun CSA C2.1-06(R2022) ati CSA C802.2022 duro idanwo, idanwo idena idabobo, ati idanwo jijo 24h ni 20kPa. Gbogbo awọn nkan ti kọja: ṣiṣe ti de 98.94%, idabobo idabobo pade awọn ibeere, ko si jijo, ati awọn afihan bọtini bii pipadanu fifuye ati foliteji impedance ni ibamu pẹlu awọn pato.

pole mounted 3 phase transformers test
pole mounted 3 phase transformers routine tests

 

 

04 Iṣakojọpọ ati Sowo

pole mounted 3 phase transformers packing
pole mounted 3 phase transformers shipping

 

 

05 Ojula ati Lakotan

Gẹgẹbi ohun elo ti o ga julọ{0} ẹrọ pinpin agbara ṣiṣe ni ibamu ni ibamu pẹlu awọn iṣedede agbaye CSA (CSA C2.1{6}}06(R2022) & CSA C802.1-13(R2022)) ati pe o ni ifọwọsi ni kikun nipasẹ awọn idanwo ṣiṣe deede, 112.5kVA yi pada duro{1}legbese mẹta{1} pẹlu iṣẹ ṣiṣe iyipada giga 98.74%, iṣẹ iṣelọpọ foliteji iduroṣinṣin, ati apẹrẹ aabo ita gbangba ti o lagbara. O ṣe deede ni pipe si awọn oju iṣẹlẹ oniruuru gẹgẹbi isọdọtun nẹtiwọọki pinpin ilu, ipese agbara ọgba-iṣẹ, ati agbegbe ina agbegbe latọna jijin. Apapọ idabobo idabobo ifaramọ, ilana foliteji kongẹ, gigun{13}}ogbodiyan{14}}pipe ipata, ati iṣẹ ṣiṣe kekere ati awọn idiyele itọju, kii ṣe opin nikan{16}} ibeere pataki olumulo fun iduroṣinṣin agbara ṣugbọn o tun ṣe deede pẹlu agbara{17} fifipamọ erongba ti awọn iṣagbega nẹtiwọọki pinpin. Igbẹkẹle, iṣẹ-giga, ati ojutu pinpin agbara ti o wulo, o funni ni ilọsiwaju ati atilẹyin agbara igbẹkẹle fun ọpọlọpọ awọn oju iṣẹlẹ ohun elo foliteji kekere.

CSA international standards

 

Awọn afiwe Gbona: polu agesin 3 alakoso Ayirapada, olupese, olupese, owo, iye owo

Fi ibere ranṣẹ