75 kVA Pole Amunawa Amunawa-7.97 / 0.12 / 0.24 kV|Canada 2024

75 kVA Pole Amunawa Amunawa-7.97 / 0.12 / 0.24 kV|Canada 2024

Orilẹ-ede Ifijiṣẹ: Canada 2024
Agbara: 75kVA
Foliteji: 7.97/13.8Y-0.12 (0.24) kV
Ẹya ara ẹrọ: pẹlu ko si; fifuye tẹ ni kia kia changer
Fi ibere ranṣẹ

 

 

75 kva pole mounted transformer-front-view

Scotech 75 kVA òpó tí a gbé transformer - pọ́n, dídára, àti agbára ìgbẹ́kẹ̀lé fún àwọn nẹ́tíwọ́kì ìpínkiri òde òní.

 

01 Gbogbogbo

1.1 Project Apejuwe

Awọn wọnyi ni 75 kVA ẹyọkan -pole ti a gbe sori awọn transformers ti Scotech ṣe.Òpó - tí a gbé àwòránsokale giga - ina foliteji si awọn ipele ti o yẹ fun awọn ile ati awọn iṣowo kekere, ni idaniloju ipese agbara iduroṣinṣin ni ilu ati igberiko. Awọn oluyipada wọnyi ti wa ni okeere si Ilu Kanada, ni ibamu ni kikun pẹlu awọn iṣedede IEEE C57.12.20 ati pade awọn ibeere iwulo ode oni fun ṣiṣe agbara.

Ilana naa pẹlu awọn ẹya 8 ti oluyipada 75 kVA. Ẹyọ kọọkan jẹ apẹrẹ fun foliteji giga ti 7.97/13.8Y kV ati kekere foliteji ti 120/240 V pipin{7}. Ni ipese pẹlu awọn bushings foliteji giga meji ati awọn bushings foliteji kekere mẹta, oluyipada naa ṣe idaniloju iṣẹ igbẹkẹle fun awọn ohun elo iṣowo ibugbe ati ina.

Oluyipada naa pese awọn ipo titẹ mẹrin ni ẹgbẹ foliteji giga pẹlu iwọn ti ± 2 × 2.5%, fifun ni irọrun awọn ohun elo lati ṣatunṣe foliteji ni ibamu si awọn ipo laini.

Pẹlu ikọlu ti o ni iwọn 2.1%, ko si - pipadanu fifuye ti 0.148 kW, ati pipadanu ẹru ti 0.675 kW, o ṣe afihan ṣiṣe giga ati awọn adanu iṣẹ ṣiṣe kekere. O gba ONAN itutu agbaiye, aluminiomu windings, ati afikun polarity, apẹrẹ fun iwapọ iwọn ati ki o rọrun ọpá - fifi sori.

Oluyipada naa tun ni ipese pẹlu ọga imuni iṣẹ abẹ, gbigba isọpọ ti awọn ẹrọ aabo fun ilọsiwaju aabo ati igbẹkẹle ninu awọn nẹtiwọọki pinpin.

 

 

1.2 Imọ pato

75kVA polu agesin transformer sipesifikesonu ati data dì

Jišẹ si
Canada
Odun
2024
Iru
Nikan alakoso polu agesin transformer
Standard
IEEE C57.12.20
Ti won won Agbara
75 kVA
Igbohunsafẹfẹ
60HZ
Polarity
Àfikún
Ẹgbẹ Vector
Ii6
Primary Foliteji
7.97 / 13.8Y kV
Secondary Foliteji
120/240V
Ohun elo Yiyi
Aluminiomu
Ipalara
2.1%
Ọna Itutu
ONAN
Tẹ Ayipada
NLTC
Ibiti titẹ ni kia kia
±2X2.5%
Ko si Ipadanu Ẹru
0,148 kW
Lori Ipadanu Fifuye
0,675 kW
Awọn ẹya ẹrọ
gbaradi arrester Oga

 

1.3 yiya

75kVA polu agesin transformer iyaworan ati nameplate

75 kva pole mounted transformer-outline-drawing 75 kva pole mounted transformer-nameplate

 

 

02 iṣelọpọ

2.1 mojuto

75 kVA ẹyọkan -ọpa ipele{2}} ti a gbe sokelo awọn ohun elo irin silikoni to gaju{{0}. Silikoni, irin jẹ ohun elo ti o wọpọ julọ fun awọn ohun kohun ẹrọ iyipada. O ni awọn ohun-ini oofa, pẹlu permeability giga ati awọn adanu mojuto kekere. Ti a fiwera si awọn ohun kohun laminated ibile, awọn ohun kohun ọgbẹ jẹ iwuwo fẹẹrẹ, ti o mu ki iṣelọpọ ti iwapọ diẹ sii ati awọn ayirapada iwuwo fẹẹrẹ.

75 kva pole mounted transformer-amorphous-core

 

2.2 Yiyi

75 kva pole mounted transformer-coils

Awọn yikaka ti oluyipada jẹ iṣẹ ọwọ ti oye nipasẹ awọn oṣiṣẹ oniwosan ti o ni iriri diẹ sii ju ọdun mẹwa lọ. Iwọn kekere -foliteji yiyi jẹ foil-egbo, ati pe giga{3}}giga foliteji jẹ ọgbẹ waya{4}, pẹlu iṣakoso deede ti ẹdọfu lati yago fun gbigbe bankanje. Inter- turn and inter- idabobo Layer ni a farabalẹ lo lati yago fun itusilẹ apa kan.

 

2.3 ojò

Ojò idana iyipo jẹ ti irin ìwọnba. Tinrin - imọ-ẹrọ nínàá dì jẹ ki ideri ati isalẹ fẹẹrẹ ati ki o lagbara. Ojò ti wa ni kikun edidi. Apẹrẹ yii jẹ ki o ni ibamu si agbegbe ati diẹ sii ni igbẹkẹle ni lilo. O ṣiṣẹ daradara fun ita gbangba ipese agbara idilọwọ.

75 kva pole mounted transformer mild steel cylindrical fuel tank

 

2.4 ik Apejọ

75 kva pole mounted transformer-activepart

Bii o ṣe le fi okun ati ọgbẹ ọgbẹ sori ẹrọ: Lakọọkọ, dubulẹ C{0}} mojuto alapin akọkọ (nṣisi ti nkọju si oke bii “U”). Mu okun naa ki o si fi iho aarin rẹ ni kikun si ẹsẹ kan ti mojuto, titari si isalẹ si isalẹ. Mu C{3} mojuto keji, so ge rẹ pọ ni pipe pẹlu gige koko akọkọ. Fi rọra pa a titi ti awọn ẹya meji yoo fi darapọ ni kikun. Fi sori ẹrọ ni oke ati isalẹ clamping farahan, fi awọn gun skru.

 

 

03 Idanwo

Idanwo baraku

1. Resistance wiwọn

2. Awọn idanwo ipin

3. Ipele{1}} Idanwo ibatan

4. Ko si Awọn ipadanu fifuye ati Ko si fifuye lọwọlọwọ

5. Awọn ipadanu fifuye, Foliteji Impedance ati ṣiṣe

6. Applied Foliteji Igbeyewo

7. Induced Foliteji withstand Igbeyewo

8. Idanwo Leak pẹlu Ipa fun Liquid Immersed Transformers

9. Idiwọn Resistance Insulation

10. Oil Dielectric igbeyewo

11. Monomono Impulse Igbeyewo

 

75 kva pole mounted transformer-electrical-test
75 kva pole mounted transformer-performance-test

 

Awọn abajade Idanwo

Rara.

Nkan Idanwo

Ẹyọ

Awọn iye gbigba

Iwọn Iwọn

Ipari

1

Awọn wiwọn Resistance

%

/

/

Kọja

2

Awọn Idanwo Ipin

%

Iyapa ti ipin foliteji lori titẹ ni akọkọ: Kere tabi dọgba si 0.5%

Aami asopọ: Ii6

-0.03

Kọja

3

ipele{0}}awọn idanwo ibatan

/

Àfikún

Àfikún

Kọja

4

Ko si - awọn adanu fifuye ati lọwọlọwọ igbadun

%

kW

t:85 iwọn

I0 :: pese iye iwọn

P0: pese iye iwọn

Ifarada fun ko si pipadanu ẹru jẹ +10%

0.24(100%)

0.46(105%)

0.144(100%)

0.167(105%)

Kọja

5

Fifuye adanu impedance foliteji ati ṣiṣe

%

kW

kW

t:85 iwọn

Z%: iye iwọn

Pk: iye iwọn

Pt: iye iwọn

ifarada fun ikọjujasi jẹ ± 10%

ifarada fun pipadanu fifuye lapapọ jẹ +6%

2.19

0.688

0.838

99.19

Kọja

6

Applied Foliteji Igbeyewo

kV

HV: 34kV 60s

LV: 10kV 60s

Ko si iparun ti foliteji idanwo waye

Kọja

7

Induced Foliteji withstand Igbeyewo

kV

Foliteji ti a lo (KV):

15.94

Iye akoko:40

Igbohunsafẹfẹ (HZ): 150

Ko si iparun ti foliteji idanwo waye

Kọja

8

Idanwo jijo

kPa

Ipa titẹ: 20kPA

Iye akoko: 12h

Ko si jijo ati ko si

Bibajẹ

Kọja

9

Idiwon Resistance idabobo

HV&LV si Ilẹ:

97.1

/

HV{0}LV si Ilẹ

36.1

LV-HV si Ilẹ

45.5

10

Idanwo Dielectric Epo

kV

Ti o tobi ju tabi dọgba si 45

55.50

Kọja

11

Idanwo imunmi ina

kV

ni kikun igbi, Idaji igbi

Ko si iparun ti foliteji idanwo waye

Kọja

 

 

04 Iṣakojọpọ ati Sowo

75 kva pole mounted transformer-packaging
 
75 kva pole mounted transformer-wooden crate packaging
 

05 Ojula ati Lakotan

75 kVA ẹyọkan -pole ti a gbe sori ẹrọ iyipada jẹ ti a ṣe fun Ilu Kanada ni ọdun 2024. O tẹle IEEE C57.12.20. O ṣiṣẹ lori 13.8 kV ti o wa lori ilẹ- awọn ọna ṣiṣe wye o si funni ni pipin 120/240 V{8}}jade ipele fun awọn ile ati awọn iṣowo kekere.

Awọn transformer ni o ni agbara to ga{0}} irin silikoni mojuto. Ko tọju pipadanu fifuye - ni 0.148 kW ati pipadanu fifuye ni 0.675 kW. O nṣiṣẹ pẹlu ṣiṣe giga ati idiyele iṣẹ kekere. Awọn yiyi jẹ aluminiomu, pẹlu bankanje -egbo LV coils ati waya -egbo HV coils. Iṣẹ ṣiṣe yikaka jẹ nipasẹ awọn oṣiṣẹ ti oye, ni idaniloju idabobo ti o lagbara ati iṣẹ ailewu.

Awọn ojò ti wa ni ṣe ti ìwọnba irin. O ti ni edidi ni kikun, ina, ati lagbara. O funni ni aabo to dara ni ita ati ṣiṣe daradara ni iṣẹ igba pipẹ-. Ẹya naa tun ni ọga imuni iṣẹ abẹ, eyiti o jẹ ki o rọrun lati ṣafikun aabo.

SCOTECH Ayirapada ti wa ni itumọ ti si okeere awọn ajohunše. Awọn ọja wa fi agbara pamọ, dinku awọn adanu, ati fun agbara iduroṣinṣin. A pese ailewu ati awọn solusan ti a fihan ti o mu ilọsiwaju iṣẹ akoj ni gbogbo ọjọ.

75 kva pole mounted transformer-left-view

Awọn afiwe Gbona: Awọn olupilẹṣẹ ti a gbe sori ọpa, olupese, olupese, idiyele, idiyele

Fi ibere ranṣẹ