20 MVA Power Ipese Amunawa-66/11 kV|South Africa 2025

20 MVA Power Ipese Amunawa-66/11 kV|South Africa 2025

Orilẹ-ede: South Africa 2025
Agbara: 20 MVA
Foliteji: 66/11 kV
Ẹya: pẹlu OLTC
Fi ibere ranṣẹ

 

 

20 MVA power supply transformer

Ti o tọ ati lilo daradara, epo - awọn transformers ti a rìbọmi nfi agbara to lagbara fun ina mọnamọna rẹ!

 

01 Gbogbogbo

1.1 Project abẹlẹ

20 MVA epo immersed power transformer ti a fi jiṣẹ si South Africa ni 2025. Agbara ti a ṣe ayẹwo ti transformer jẹ 20 MVA pẹlu ONAN/ONAF itutu agbaiye. Foliteji akọkọ jẹ 66 kV pẹlu ± 6 * 1.67% ibiti o tẹ ni kia kia (OLTC), foliteji keji jẹ 11 kV, wọn ṣẹda ẹgbẹ fekito ti YNd11.

OLTC jẹ awoṣe asopọ Y{0} pẹlu gaasi isọdọtun lori iyipada ati olubasọrọ irin-ajo lori isọdọkan gaasi. Oluyipada ipese agbara MVA 20 ti ni ipese pẹlu akọmọ imudani monomono lati daabobo ohun elo lati awọn iyalẹnu ina. Ni ipese pẹlu thermometer yikaka pẹlu olubasọrọ irin ajo itaniji ati ẹrọ oluyipada lọwọlọwọ ti o nilo fun iwọn otutu yikaka. thermometer ipele epo pẹlu olubasọrọ irin ajo itaniji ati mita ipele epo pẹlu itaniji ipele epo kekere. Ni afikun, apoti ebute ati awọn aaye miiran ti wa ni ipese pẹlu awọn igbona, ati pe ẹgbẹ folti kekere ti ni ipese pẹlu apoti okun kekere foliteji lati rii daju pe iṣẹ deede ni agbegbe iwọn otutu kekere. Oluranlọwọ ipese agbara agbara foliteji 110V, yipada drive motor ipese agbara foliteji 220V, igbona ipese agbara foliteji 220V.

 

1.2 Imọ pato

20 MVA epo immersed agbara transformer iru ati iwe data

Jišẹ si
gusu Afrika
Odun
2025
Iru
Epo immersed agbara transformer
Standard
IEC60076
Ti won won Agbara
20 MVA
Igbohunsafẹfẹ
50 HZ
Ipele
3
Itutu agbaiye
ONAN/ONAF
Primary Foliteji
66 kV
Secondary Foliteji
11 kV
Ohun elo Yiyi
Ejò
Angular nipo
YNd11
Ipalara
8%
Tẹ Ayipada
OLTC
Ibiti titẹ ni kia kia
±6*1.67%
Ko si Ipadanu Ẹru
20 (± 10%) kW
Lori Ipadanu Fifuye
105 (± 10%) kW
Awọn ẹya ẹrọ
Standard iṣeto ni

 

1.3 Yiya

20 MVA epo immersed agbara transformer aworan atọka ati iwọn.

20 MVA power supply transformer diagram 20 MVA power supply transformer nameplate

 

 

02 iṣelọpọ

2.1 mojuto

Awọn ẹya ara ẹrọ mojuto ẹya ẹya laminated, ninu ọpọ tinrin irin sheets tolera papo. Awọn sisanra ti iwe kọọkan jẹ iṣiro ni deede lati rii daju idinku pipadanu ti o dara julọ lakoko ti o duro ni ṣiṣan oofa iṣẹ ti n yipada. A ṣe apẹrẹ mojuto bi Circuit oofa pipade, ni idaniloju pe ṣiṣan oofa le kaakiri daradara laarin mojuto, nitorinaa imudara iṣẹ ṣiṣe ẹrọ oluyipada. Circuit oofa pipade ṣe iranlọwọ lati dinku awọn adanu oofa jijo ati mu iṣẹ ṣiṣe pọ si.

 

2.2 Yiyi

20 MVA power supply transformer winding

Yiyi lilọsiwaju n tọka si awọn iyipo laarin yiyi ti o jẹ ọgbẹ laisi idalọwọduro tabi ipin. Eto yii ngbanilaaye lọwọlọwọ lati ṣe aaye oofa iduroṣinṣin laarin yiyi, idinku awọn adanu itanna ati eewu awọn aṣiṣe ti o ṣẹlẹ nipasẹ awọn onirin fifọ tabi awọn aaye asopọ. Nitori awọn lemọlemọfún oniru, o kí diẹ aṣọ lọwọlọwọ pinpin, dindinku awọn Ibiyi ti gbona muna ati ki o mu awọn ìwò ṣiṣe ti awọn transformer.

 

2.3 ojò

Ṣe apẹrẹ awọn apẹrẹ irin ti a ge nipasẹ titẹ ati kika lati ṣẹda eto ikarahun ita ti ojò. Lo awọn ilana alurinmorin MIG tabi TIG lati ṣe alurinmorin awọn paati patapata, iṣakoso didara weld lati ṣe idiwọ awọn n jo iwaju. Mọ ojò welded lati yọ oxides ati awọn iṣẹku epo kuro. Fi ipata kan- alakoko sooro ati ẹwu oke si ita ojò lati mu ilọsiwaju si ipata ati oju ojo. Lu awọn ihò pataki lori ojò lati fi sii ẹnu-ọna, itọsi, ẹmi, iwọn ipele epo, thermometer, ati awọn ẹya miiran lati rii daju iṣẹ ṣiṣe. Fi sori ẹrọ awọn ẹya atilẹyin ati awọn asopọ lati rii daju iduroṣinṣin ojò lakoko iṣẹ.

20 MVA power transformer steel plate oil tank

 

2.4 ik Apejọ

20 MVA power supply transformer final assembly

Yikakiri iṣelọpọ ati fifi sori: Fi sori ẹrọ ni kekere foliteji yikaka lori mojuto akọkọ, atẹle nipa awọn ga foliteji yikaka.

Apejọ ara: Gbe awọn mojuto ati yikaka sinu Amunawa ojò ki o si fix wọn ni ipo. Fi awọn oluyipada tẹ sori ẹrọ ati awọn ẹya inu inu miiran.

Igbale ati Epo kikun: Yọ afẹfẹ kuro ninu awọn coils ati ojò nipasẹ igbale lati ṣẹda ipo igbale. Kun ojò pẹlu epo iyipada lati rii daju idabobo ati iranlọwọ itutu agbaiye.

Fifi sori ẹrọ ẹya ẹrọ: Fi sori ẹrọ awọn ẹya ita gẹgẹbi awọn olutọpa, awọn olutọju epo, awọn relays gaasi, ati awọn falifu iderun titẹ.

 

 

03 Idanwo

1. Wiwọn awọn gaasi tituka ni omi dielectric lati inu iyẹwu epo lọtọ kọọkan ayafi iyẹwu iyipada oluyipada.

2. Iwọn wiwọn foliteji ati ṣayẹwo ti iṣipopada alakoso

3. Wiwọn ti yikaka resistance

4. Ṣayẹwo ti Core Ati Idabobo fireemu Fun Awọn Ayirapada Immersed Liquid Pẹlu Core Tabi Idabobo fireemu

5. Wiwọn ti DC Insulation Resistance Laarin kọọkan Yiyi Si Earth Ati Laarin awọn windings

6. Ipinnu ti capacitances windings si aiye ati laarin windings

7. Idanwo Foliteji ti a lo (AV)

8. Wiwọn ti Bẹẹkọ - Pipadanu ati lọwọlọwọ

9. Induced Foliteji withstand Igbeyewo

10. Wiwọn Kukuru -Imudanu ayika ati Pipadanu Ẹru

11. Wiwọn ti tituka gasses ni dielectric omi lati kọọkan lọtọ epo kompaktimenti ayafi diverter yipada kompaktimenti

12. Idanwo Leak Pẹlu Ipa Fun Liquid{1}}Awọn Ayirapada Immersed (Igbeyewo Titẹrọ)

 

20 MVA power supply transformer testing
20 MVA power supply transformer fat

 

 

04 Iṣakojọpọ ati Sowo

20 MVA power supply transformer packing
iṣakojọpọ
20 MVA power supply transformer shipping
sowo

 

05 Ojula ati Lakotan

O ṣeun fun gbigba akoko lati kọ ẹkọ nipa epo wa{0}}awọn transformer agbara immersed. Gẹgẹbi paati mojuto ni gbigbe agbara ati pinpin, awọn ọja wa jẹ olokiki fun iṣẹ iyasọtọ wọn, iduroṣinṣin igbẹkẹle, ati idabobo daradara ati awọn agbara itutu agbaiye. Boya ni awọn apa ile-iṣẹ tabi agbegbe iṣowo, epo{3}} awọn oluyipada iyipada le pade awọn ibeere agbara oniruuru, ni idaniloju aabo ati iṣẹ ṣiṣe ti awọn eto. Yiyan wa tumọ si yiyan imọ-ẹrọ to ti ni ilọsiwaju, atilẹyin ọjọgbọn, ati itọju alabara ti nlọ lọwọ. A nireti lati ṣe ajọṣepọ pẹlu rẹ lati jẹki igbẹkẹle ati ṣiṣe ti awọn eto agbara rẹ. O ṣeun fun akiyesi ati igbẹkẹle rẹ!

20 MVA power supply transformers

 

Awọn afiwe Gbona: olupilẹṣẹ ipese agbara, olupese, olupese, owo, iye owo