6 MVA Meta Alakoso Agbara Amunawa-33 / 6.6 kV|South Africa 2024

6 MVA Meta Alakoso Agbara Amunawa-33 / 6.6 kV|South Africa 2024

Orilẹ-ede: South Africa 2024
Agbara: 6 MVA
Foliteji: 33/6.6 kV
Ẹya: Gbona galvanized
Fi ibere ranṣẹ

 

 

three phase power transformer

Innovation ṣe awakọ didara julọ - a daabobo gbogbo watt ti agbara pẹlu imọ-ẹrọ!

 

01 Gbogbogbo

1.1 Project abẹlẹ

Awọn transformer agbara pinpin 6 MVA Epo - ni a fi jiṣẹ si South Africa ni ọdun 2024. Agbara ti epo Immersed transformer jẹ 6000 kVA pẹlu itutu ONAN, foliteji akọkọ jẹ 33 kV pẹlu ± 2*3% ibiti o tẹ ni kia kia (NLTC), foliteji keji jẹ 6.6 kV, wọn ṣẹda ẹgbẹ Dyn 1.

Awọn oluyipada 6MVA jẹ lilo pupọ ni ile-iṣẹ, awọn maini, awọn ile-iṣẹ agbara ati awọn ibudo nla{1}, ati pe o le pese agbara iduroṣinṣin fun awọn mọto nla, awọn ẹrọ mimu abẹrẹ, awọn ẹrọ alurinmorin ati awọn ohun elo giga{2}} miiran. Ni afikun, iṣẹ ṣiṣe ti o munadoko ati igbẹkẹle ati isọdọtun fifuye to lagbara jẹ ki o ṣe ipa pataki ninu gbigbe agbara ati awọn ọna ṣiṣe pinpin.

 

 

1.2 Imọ pato

6 MVA agbara transformer sipesifikesonu ati data dì

Jišẹ si
gusu Afrika
Odun
2024
Iru
Epo Immersed Power Amunawa
Standard
IEC 60076
Ti won won Agbara
6MVA
Igbohunsafẹfẹ
50 HZ
Ipele
Mẹta
Itutu agbaiye
ONAN
Primary Foliteji
33kV
Secondary Foliteji
6.6kV
Ohun elo Yiyi
Ejò
Ẹgbẹ Vector
YNa0
Ipalara
0.98%
Tẹ Ayipada
NLTC
Ibiti titẹ ni kia kia
±2*3%
Ko si Ipadanu Ẹru
6.2KW
Lori Ipadanu Fifuye
39KW
Awọn ẹya ẹrọ
Standard iṣeto ni

 

1.3 Yiya

Iyaworan aworan iyipada agbara MVA 6 ati iwọn.

20251016140248384177

20251016140249385177

20251016140249386177

 

 

02 iṣelọpọ

2.1 mojuto

Isọpọ igbesẹ ti o ni itara ni kikun ni a gba lati mu itọsọna ṣiṣan pọ si, imukuro isẹlẹ ekunrere ṣiṣan agbegbe ni isẹpo ti mojuto irin, din ko - pipadanu fifuye ati rara{1} fifuye lọwọlọwọ ti mojuto irin, ati dinku ariwo transformer. Lati le mu agbara lati koju kukuru kukuru, nọmba awọn eekanna titẹ ni a pin kakiri ni ayika awo titẹ, ati awọn agekuru giga ati isalẹ ti oke ati isalẹ ti wa ni asopọ nipasẹ awọn opo atilẹyin, ki mojuto iron di odidi. Ni afikun, awọn dada ti awọn mojuto iwe ti a bo pẹlu ohun alumọni, irin dì pataki opin lẹ pọ, ki awọn ohun alumọni, irin dì ati awọn dì ti wa ni iwe adehun papo, ati awọn irin mojuto di ara kan lẹhin curing. Awọn atilẹyin igi ti o ni itanna ti o ga julọ ni a lo laarin apa isalẹ ti ara ati odi ti ojò, ṣiṣe apa isalẹ ti ara ni ailewu ati ipo igbẹkẹle.

3 phase transformer core

 

2.2 Yiyi

continuous winding

Ni lilọsiwaju yikaka, awọn onirin ti wa ni idayatọ ni wiwọ ati boṣeyẹ, ki pinpin aaye itanna jẹ iwọntunwọnsi diẹ sii. Apẹrẹ yii kii ṣe idinku awọn aaye gbigbona agbegbe nikan ti o le ṣe ipilẹṣẹ ni yiyi, ṣugbọn o tun dinku kikọlu itanna, nitorinaa imudara ṣiṣe gbogbogbo ati iduroṣinṣin ti oluyipada. Paapa ni igbohunsafẹfẹ giga tabi awọn ohun elo agbara giga, lilọ kiri lemọlemọ le dinku awọn adanu ni pataki ati mu iyara esi ati ifamọ ti ẹrọ oluyipada.

 

2.3 ojò

Ti a ṣe ẹrọ fun idiyele 6MVA kan, ojò transformer yii n pese atilẹyin ẹrọ fun mojuto, ni epo idabobo naa, ati ṣiṣe itusilẹ ooru ti o munadoko nipasẹ awọn ogiri corrugated tabi finned. O ṣe idaniloju aabo pipe ti awọn paati inu lati agbegbe.

step down power transformer

 

2.4 ik Apejọ

transformer 3 phase

Mojuto ati Yika Apejọ: Fi sori ẹrọ daradara awọn windings pẹlẹpẹlẹ si mojuto ati ṣiṣe awọn itọju idabobo pataki bi o ṣe nilo nipasẹ awọn pato.

Ti nṣiṣe lọwọ Apejọ Apá: Fi sii mojuto ti a pejọ ati awọn windings sinu epo epo, ni idaniloju deede ni fifi sori ẹrọ ati awọn ibeere idabobo.

Itọju Epo: Gbigbe epo idabobo sinu ojò fun idabobo ati itutu awọn ẹya ti nṣiṣe lọwọ, lakoko ti o tun ṣayẹwo didara epo ati ipele.

Fifi sori Asomọ: Fifi sori ẹrọ awọn ẹrọ itutu agbaiye, awọn relays aabo, awọn ohun elo, ati awọn falifu lati rii daju iṣẹ ailewu ati iṣẹ-ṣiṣe ti oluyipada.

 

 

03 Idanwo

1. Wiwọn awọn gaasi tituka ni omi dielectric lati inu iyẹwu epo lọtọ kọọkan ayafi iyẹwu iyipada oluyipada.

2. Wiwọn Iwọn Foliteji ati Ṣayẹwo ti Iṣipopada Alakoso

3. Wiwọn ti Yika Resistance

4. Wiwọn ti DC Insulation Resistance Laarin kọọkan Yiyi Si Earth Ati Laarin awọn Windings

5. Applied Foliteji Igbeyewo

6. Wiwọn ti Bẹẹkọ{{1}Ipadanu fifuye ati lọwọlọwọ

7. Induced Foliteji Igbeyewo

8. Wiwọn Kukuru - Imudanu ayika ati Pipadanu Ẹru

9. Idanwo Leak Pẹlu Ipa Fun Liquid{1}}Awọn Ayirapada Immersed

iec 60076

 

04 Iṣakojọpọ ati Sowo

led power supply transformer
 
power transformer company
 
 

05 Ojula ati Lakotan

Ni ipari, epo - awọn oluyipada pinpin immersed, pẹlu iṣẹ itutu agbaiye giga wọn ati apẹrẹ to lagbara, jẹ yiyan pipe fun ọpọlọpọ awọn ọna ṣiṣe agbara. Wọn kii ṣe pese iṣẹ itanna to dara julọ ṣugbọn tun ṣetọju ṣiṣe ati iduroṣinṣin lakoko iṣẹ ṣiṣe gigun. Boya ni awọn nẹtiwọọki pinpin ilu tabi awọn papa itura ile-iṣẹ, awọn oluyipada wọnyi le pade awọn iwulo agbara rẹ ati rii daju ipese agbara ti o gbẹkẹle. A ti pinnu lati fun ọ ni awọn ojutu to dara julọ nipasẹ imọ-ẹrọ ilọsiwaju ati iṣẹ didara ga-. O ṣeun fun akiyesi rẹ ati igbẹkẹle ninu epo wa- awọn transformers pinpin immersed; a nireti lati ṣe ifowosowopo pẹlu rẹ lati ṣẹda ọjọ iwaju didan.