500 kVA Meta Alakoso Pinpin Amunawa-4.16 / 0,6 kV|Canada 2025

500 kVA Meta Alakoso Pinpin Amunawa-4.16 / 0,6 kV|Canada 2025

Orilẹ-ede: Canada 2025
Agbara: 500 kVA
Foliteji: 4.16D-0.6Y / 0.347kV
Ẹya ara ẹrọ: pẹlu kirk bọtini
Fi ibere ranṣẹ

 

 

three phase distribution transformer

Ko si Ojuran, Ko Jade Ni Agbara – Agbara Iwapọ ti Paadi{0}}Awọn Ayirapada ti a gbe soke.

 

 

01 Gbogbogbo

1.1 Project Apejuwe

500 kVA mẹta alakoso pad agesin transformer ti a jišẹ si America ni 2025. Awọn won won agbara ti awọn transformer jẹ 500 kVA pẹlu ONAN itutu. Foliteji akọkọ jẹ 4.16D kV pẹlu ± 2 * 2.5% ibiti o tẹ ni kia kia (NLTC), foliteji keji jẹ 0.6Y / 0.347kV, wọn ṣẹda ẹgbẹ fekito ti Dyn1.

Paadi 500kVA yii{1} ti a gbe sori ẹrọ awọn ẹya ara ẹrọ awọn atunto amọja ti a ṣe apẹrẹ fun aabo imudara, igbẹkẹle, ati resilience ni wiwa awọn agbegbe iṣẹ.

Ko dabi awọn ẹya boṣewa, o ṣafikun eto interlock Kirk Key lati fi ipa mu awọn ilana ṣiṣe ailewu ati ṣe idiwọ iraye si lairotẹlẹ si awọn paati agbara, ni idaniloju ibamu pẹlu awọn ilana aabo to muna. Ni afikun, o ti ni ipese pẹlu awọn imuni igbonwo fun aabo apọju iwọn, pataki ni awọn agbegbe ti o ni itara si awọn ikọlu monomono tabi awọn idamu grid. Oluyipada naa tun pẹlu awọn ipese oran jigijigi, nfi imuduro iduroṣinṣin igbekalẹ rẹ lagbara lati koju iṣẹ ṣiṣe jigijigi, ṣiṣe ki o dara fun imuṣiṣẹ ni awọn agbegbe nla-iwariri ilẹ-. Awọn ẹya to ti ni ilọsiwaju wọnyi ni iṣakojọpọ aabo iṣẹ ṣiṣe, idinku iṣẹ abẹ, ati isọdọtun ajalu, ṣiṣe ounjẹ si awọn ohun elo amayederun to ṣe pataki gẹgẹbi awọn ohun elo ile-iṣẹ, awọn nẹtiwọọki ohun elo, ati awọn eto agbara pajawiri ni awọn agbegbe agbegbe jigijigi.

 

 

 

1.2 Imọ pato

500 KVA paadi agesin transformer iru ati data dì

Jišẹ si
Canada
Odun
2025
Iru
Paadi agesin transformer
Standard
CSA C227.4:21
Ti won won Agbara
2500 kVA
Igbohunsafẹfẹ
60HZ
Ipele
3
Ifunni
Radial
Iwaju
Òkú
Itutu agbaiye
ONAN
Primary Foliteji
4.16D kV
Secondary Foliteji
0.6Y / 0.347 kV
Ohun elo Yiyi
Aluminiomu
Angular nipo
Dyn1
Ipalara
3.1%
Tẹ Ayipada
NLTC
Ibiti titẹ ni kia kia
±2*2.5%
Ko si Ipadanu Ẹru
0,36 kW
Lori Ipadanu Fifuye
9 kW

 

 

1.3 Yiya

500 kVA paadi agesin transformer aworan atọka yiya ati iwọn.

three phase distribution transformer diagram

three phase distribution transformer drawing

three phase distribution transformer nameplate

 

 

02 iṣelọpọ

2.1 mojuto

CSA - paadi ti o ni ifaramọ - transformer ti a fi sori ẹrọ n ṣepọpọ -egbo egbo silikoni ti o ga, ti a ṣe lati ba agbara ijafafa ati awọn iṣedede iṣẹ ṣiṣe mu. Itumọ ọgbẹ n ṣe idaniloju titete ṣiṣan oofa ti o dara julọ, ni pataki idinku ko si -awọn adanu fifuye nipasẹ 15-25% ni akawe si awọn ohun kohun ti ibile lakoko ti o nmu ilodi si irẹpọ- pataki fun awọn grids ode oni pẹlu ilaluja agbara isọdọtun giga. CSA-ifọwọsi fun ailewu ati igbẹkẹle.

CSA-compliant

 

2.2 Yiyi

transformer winding machine

Amunawa yiyi okun yii nlo imọ-ẹrọ ti o ni ilọsiwaju Coil Winding, ti o npapọ kekere-afẹfẹ foil yikaka (foili aluminiomu) ati giga{1}} wiwọ Layer foliteji (waya bàbà) fun ṣiṣe giga ati igbẹkẹle. Apa kekere -foliteji n gba olona{4}}Layer ajija foil yikaka, ti o funni ni eto iwapọ, itusilẹ ooru ti o ga julọ, ati kukuru kukuru ti o lagbara-irapada ayika. Awọn ẹya giga ti ẹgbẹ foliteji {{7} awọn ẹya ara ẹrọ yikaka okun waya Ejò, ti n ṣe idaniloju iṣiṣẹ adaṣe to dara julọ ati agbara ẹrọ. Pẹlu apẹrẹ coaxial ti n ṣatunṣe iwuwo agbara ati igbega iwọn otutu.

 

2.3 ojò

Ojò Amunawa yii ni a ṣe lati Irin Irẹwẹsi, n funni ni agbara ẹrọ ti o lagbara ati agbara gigun-. Ojò ti wa ni welded ati ki o toju pẹlu egboogi - ipata bo (fun apẹẹrẹ, kikun tabi galvanization) lati koju si lile ita gbangba awọn ipo. Ti di edidi sibẹ ti o ni imunadoko igbona pẹlu awọn egungun imuduro lati jẹki idiwọ titẹ, idilọwọ idibajẹ lati imugboroosi epo tabi kukuru- awọn ipa ipa-kiri. Awọn ẹya boṣewa gẹgẹbi awọn ebute oko kikun epo, awọn afihan ipele, ati awọn ẹrọ iderun titẹ ni idaniloju ailewu ati itọju irọrun. Iye owo ìwọnba Irin - imunadoko ati igbẹkẹle jẹ ki o jẹ ohun elo ti o fẹ fun alabọde{10} si{11}} awọn transformer pinpin nla.

welded transformer tank

 

2.4 Kirk Key

20251203092939882177

KIRK Iru F interlock jẹ bọtini kan ti a ṣiṣẹ interlock darí ti o dara fun iṣakoso ti itanna switchgear. Ẹka boṣewa wa pẹlu irin alagbara, irin 5/8” boluti titiipa iwọn ila opin pẹlu jiju tabi irin-ajo ti 3/4”. Bọlu titii pa ni a lo lati ṣakoso yiyi tabi iṣipopada awọn ọwọ iṣiṣẹ tabi awọn yiyi ti ẹrọ iyipada itanna. Ọpọlọpọ awọn olupese ti ohun elo ẹrọ iyipada ni awọn ipese iṣagbesori wa fun awọn interlocks KIRK. Titiipa naa jẹ iṣelọpọ ni idẹ tabi irin alagbara.

 

 

03 Idanwo

 

dga test
dga oil test

 

 

04 miiran

4.1 Seismic oran ipese

Awọn ipese ìdákọ̀ró seismic fun paadi- awọn oluyipada ti a fi sori ẹrọ tọka si awọn ọna ṣiṣe idaduro ti a ti tunṣe ati awọn pato fifi sori ẹrọ ti a ṣe apẹrẹ lati ni aabo ẹyọ naa si ipilẹ ti o nipọn lakoko awọn iṣẹlẹ jigijigi. o ni awọn ẹya bii ṣaju{2}}giga giga-awọn ihò ìdákọ̀ró agbara ni ipilẹ ati lilo awọn biraketi seismic ti a fọwọsi ati awọn boluti ìdákọ̀ró. Iṣẹ akọkọ wọn ni lati ṣe idiwọ fun oluyipada lati yiyi, yiyi pada tabi sisun, nitorinaa aridaju iduroṣinṣin igbekalẹ, mimu awọn asopọ itanna, ati idilọwọ awọn eewu keji (bii awọn ina tabi awọn itujade epo) nigbati o ba tẹriba si awọn ipa isare ilẹ pato. Eyi jẹ ibeere aabo to ṣe pataki fun awọn oluyipada ti a fi sori ẹrọ ni awọn agbegbe iwariri-ilẹ-.

20251203092940883177

 

4.2 Gbigbe

marine insurance

Labẹ awọn ofin CIF, olutaja naa bo iye owo, iṣeduro okun, ati ẹru ọkọ si ibudo ti nlo (paapaa Vancouver) fun Pad{{0}Mounted Transformers ti a fi ranṣẹ si Winnipeg, Canada, pẹlu eewu gbigbe si olura ni ibudo ikojọpọ. Awọn oluyipada gbọdọ wa ni idalẹnu ninu ọrinrin{2}}awọn apoti ẹri/awọn fireemu irin pẹlu awọn ami igbega ati awọn aami atako{3}, pẹlu awọn risiti iṣowo, B/L, ati iwe-ẹri CSA. Lẹhin ẹru omi okun si Vancouver, olura naa ṣe itọju idasilẹ kọsitọmu ati gbigbe si inu ilẹ nipasẹ ọkọ oju-irin (ọjọ 5-7) tabi ọkọ nla si Winnipeg, ṣe akiyesi awọn idaduro igba otutu ti o pọju. Olutaja naa ṣe iṣeduro 110% iye ẹru, lakoko ti olura n san awọn iṣẹ-ṣiṣe ati awọn idiyele irinna ilẹ-ilẹ.

 

 

05 Ojula ati Lakotan

Gẹgẹbi paati pataki ti awọn ọna ṣiṣe pinpin agbara, Paadi {{0}Mounted Transformer n pese awọn ojutu agbara ti o gbẹkẹle, daradara, ati ore ayika fun ile-iṣẹ, iṣowo, ati awọn amayederun gbogbo eniyan. Apapọ imọ-ẹrọ imotuntun pẹlu awọn iṣedede didara to lagbara, a rii daju pe oluyipada kọọkan n pese iṣẹ pipẹ - iṣẹ ṣiṣe pipẹ ni awọn agbegbe ti o nbeere lakoko ti o nmu agbara ṣiṣe ṣiṣẹ ati idinku awọn idiyele itọju.

Boya o nilo awọn apẹrẹ ti a ṣe adani tabi ṣiṣe agbara ti o ga julọ, ẹgbẹ alamọja wa n pese opin{0}lati{1}} atilẹyin. Yan wa fun pinpin agbara ti o gbẹkẹle ati oye - ni kikọ ọjọ iwaju agbara alagbero diẹ sii.

Kan si wa loni fun a sile ojutu!

high energy efficiency

 

Awọn afiwe Gbona: Amunawa pinpin alakoso mẹta, olupilẹṣẹ, olupese, idiyele, idiyele

Fi ibere ranṣẹ