1500 KVA Amunawa iṣagbesori paadi-34.5 / 0.4 KV|AMẸRIKA 2025

1500 KVA Amunawa iṣagbesori paadi-34.5 / 0.4 KV|AMẸRIKA 2025

Orilẹ-ede: USA 2025
Agbara: 1500 kVA
Foliteji: 34.5D-0.4Y / 0,23 kV
Ẹya: pẹlu FR3 epo
Fi ibere ranṣẹ

Jiangshan Scotech Electrical Co., Ltd jẹ ọkan ninu awọn olupese ti o gbẹkẹle julọ ati awọn olupese ti 1500 kva transformer mounting pad-34.5/0.4 kv|USA 2025 ni China. Jọwọ lero ọfẹ lati ra awọn ọja to munadoko fun tita nibi ati gba awọn aworan atọka lati ile-iṣẹ wa. Kan si wa fun alaye sii.

 

transformer mounting pad

Idakẹjẹ, tamper{0}}ẹri, ati itọju{1}ore{2} transformer mounted pad n pese agbara nibiti o nilo rẹ.

 

 

01 Gbogbogbo

1.1 Project Apejuwe

1500 kVAmẹta alakoso paadi agesin transformerti a fi jiṣẹ si AMẸRIKA ni ọdun 2025. Agbara ti a ṣe iwọn ti paadi iṣagbesori transformer jẹ 1500 kVA pẹlu itutu agbaiye KNAN. Iwọn giga jẹ 34.5D kV pẹlu ± 2 * 2.5% ibiti o tẹ ni kia kia (NLTC), foliteji kekere jẹ 0.4Y / 0.23 kV, wọn ṣẹda ẹgbẹ fekito ti Dyn1.

SCOTECH nfunni ni eyi1500 kVA paadi{1} ti a gbe sori ẹrọ iyipada, apẹrẹ ati ti ṣelọpọ ni ibamu pẹluIEEE Std C57.12.34-2022. Dara fun awọn ohun elo pinpin ita gbangba (ti o to 1000m giga), oku yii{2}iwaju, loop{3}}Ẹka ti o lagbara ifunni n pese iṣẹ ṣiṣe ti o gbẹkẹle fun iṣowo, ile-iṣẹ, ati awọn nẹtiwọọki ohun elo.

Key Awọn ẹya ara ẹrọ

  • Eto itutu agbaiye – KNAN pẹlu FR3® Epo

Awọn transformer adopts aKNANọna itutu (convection adayeba ti ito ati afẹfẹ), liloFR3 ito ester adayeba. FR3 offers a high fire point (>Iwọn 300), 100% biodegradability, ati iṣakoso ọrinrin ti o ga julọ, ni pataki igbesi aye idabobo ni akawe si epo nkan ti o wa ni erupe ile aṣa.

  • Awọn Fuses Didara giga{{0} - Cooper Power Series

Ni ipese pẹluEaton Cooper Power jaraawọn fiusi: Bay mẹta {{0}O{{1}Apapọ itusilẹ Net (4000380C14CB) ati lọwọlọwọ ELSP mẹta{4}} awọn fiusi ifẹhinti (CBUC38140D100). Ijọpọ yii n pese aabo ni kikun-aibikita, pẹlu arorọpo aaye ti Bay{9}O{10}Net fuse.

  • DOE 2016 Imudara Imudara

Awọn transformer padeU.S. Ọdun 2016ṣiṣe awọn ajohunše, iyọrisi99,48% ṣiṣe- idinku awọn adanu agbara ati awọn idiyele iṣẹ lakoko atilẹyin awọn ibi-afẹde agbara agbara.

Oluyipada yii darapọ aabo ina, ojuse ayika, aabo to lagbara, ati ṣiṣe giga - ojutu ti o gbẹkẹle fun awọn ọna ṣiṣe pinpin agbara ode oni.

 

 

 

1.2 Imọ Specification

1500 kVA transformer iṣagbesori paadi iru ati data dì

Jišẹ si
USA
Odun
2025
Iru
Paadi agesin transformer
Standard
IEEE Std C57.12.34-2022 DOE 2016
Ti won won Agbara
1500 kVA
Igbohunsafẹfẹ
60HZ
Ipele
3
Ifunni
Loop
Iwaju
Òkú
Itutu agbaiye
KNAN
Primary Foliteji
34.5D kV
Secondary Foliteji
0.4y/0.23 kV
Ohun elo Yiyi
Aluminiomu
Ẹgbẹ Vector
Dyn1
Ipalara
5.75%
Iṣẹ ṣiṣe
99.48%
Tẹ Ayipada
NLTC
Ibiti titẹ ni kia kia
±2*2.5%
Ko si Ipadanu Ẹru
1.545 kW
Lori Ipadanu Fifuye
10.54 kW

 

1.3 yiya

1000 kVA transformer iṣagbesori paadi aworan atọka iyaworan ati iwọn.

transformer mounting pad diagram transformer mounting pad nameplate

 

 

02 iṣelọpọ

2.1 mojuto

transformer mounting pad core with three-limb design

Ipilẹ paadi iṣagbesori transformer gba apẹrẹ ẹsẹ mẹta-, ti o baamu ni kikun iwọn 1500 kVA ati ẹgbẹ fekito Dyn1, ati ni ibamu pẹlu IEEE C57.12.34-2022. Pipadanu ko si fifuye jẹ 1.395 kW nikan (ni iwọn 20) ati pe ko si fifuye lọwọlọwọ jẹ kekere bi 0.13%, ti n ṣe afihan ṣiṣe Circuit oofa to dara julọ ati didara ohun elo. Awọn abajade wọnyi wa lati ijabọ idanwo igbagbogbo (apakan 4.4), n ṣe afihan isonu kekere ti mojuto ati igbẹkẹle giga. Ṣiṣejade nlo agbara-giga, ohun alumọni alumọni-orun-pipadanu ọkà-pipadanu, irin pẹlu akopọ ni kikun laifọwọyi, aridaju lile mojuto ibamu ati iṣẹ oofa. Awọn ifojusi iṣelọpọ: ohun elo agbara-giga, akopọ adaṣe, apẹrẹ hysteresis kekere.

 

2.2 Yiyi

Awọn yiyi jẹ aluminiomu, pẹlu awọn foliteji ti a ṣe iwọn 34500-400Y / 230 V ati ibiti o tẹ ni kia kia ± 2 × 2.5%, ni ibamu ni pipe awọn ipilẹ apẹrẹ. Wọn ṣe ibamu pẹlu awọn ibeere IEEE C57.12.90-2021 fun aiṣedeede resistance, agbara dielectric, ati igbega otutu. Gẹgẹbi ijabọ idanwo naa, aiṣedeede resistance yikaka HV ti o pọju jẹ 0.44% nikan (daradara ni isalẹ opin 4.88%). Idanwo foliteji ti a lo kọja ni 50 kV (HV) ati 10 kV (LV) fun awọn aaya 60; Idanwo foliteji ti a fa ti kọja ni 30.8 kV ti a lo / 69 kV induced, 150 Hz fun awọn aaya 48 laisi didenukole. Nibayi, apapọ yikaka otutu jinde Kere ju tabi dogba si 65 iwọn , gbona-spot jinde Kere ju tabi dogba si 80 ìyí , ati oke epo dide Kere ju tabi dogba si 65 ìyí , aridaju gun-igba ailewu isẹ. Didara jẹ idaniloju nipasẹ awọn ẹrọ yiyi laifọwọyi pẹlu iṣakoso ẹdọfu nigbagbogbo ati ayewo idabobo laarin. Awọn ifojusi iṣelọpọ: yiyi-laifọwọyi, idabobo ilọpo meji, igbekalẹ foliteji giga.

transformer mounting pad winding

 

2.3 ojò

Ojò naa jẹ apẹrẹ ideri ti a fi idii ti a ṣe ti irin kekere, ti o ni ipese pẹlu awọn wiwu gbigbe ati awọn paadi jacking, ni kikun dara fun fifi sori ita gbangba. Awọ ati awọn iwọn tẹle iyaworan ikẹhin (Munsell 9 GY 1.5 / 2.6 ohun elo alawọ ewe). O ni ibamu pẹlu awọn ibeere IEEE C57.12.34 fun agbara ẹrọ ati aabo ipata. Ijabọ idanwo jo fihan pe lẹhin lilo titẹ 15 kPa fun awọn wakati 24, ko si jijo tabi abuku ayeraye, ti n jẹrisi iduroṣinṣin ojò. Idaniloju didara pẹlu 100% ayewo weld ati ibora-ibajẹ giga. Awọn ifojusi iṣelọpọ: apẹrẹ ideri welded, idanwo jijo titẹ wakati 24, awọ ipata-giga.

 

2.4 ik Apejọ

Apejọ ikẹhin ṣepọ awọn igbo HV ti o ya sọtọ mẹfa, awọn bushings LV simẹnti simẹnti mẹta, awọn igi ilẹ, oluyipada tẹ ni kia kia de-agbara, ati - bi afihan iṣẹ akanṣe bọtini kan -ga-didara Cooper fuses(Iru bayonet ati afẹyinti-ipin lọwọlọwọ). Apejọ ni kikun baamu awọn iyaworan ati ni ibamu pẹlu awọn iṣe IEEE fun awọn imukuro ati isọpọ ẹrọ. Awọn wiwọn idabobo idabobo fihan: HV‑LV si ilẹ 1.65 GΩ, LV‑HV si ilẹ 1.58 GΩ, ati HV&LV si ilẹ 1.12 GΩ – jina loke awọn ipilẹ ailewu aṣoju, nfihan igbẹkẹle apejọ. Didara jẹ idaniloju nipa lilo awọn paati Cooper orukọ iyasọtọ, awọn igbasilẹ apejọ ti o wa kakiri, ati ṣayẹwo-meji ti awọn iyipo to ṣe pataki. Awọn ifojusi iṣelọpọ: Awọn fuses Cooper, awọn bushings HV iyapa, 100% ijẹrisi idabobo idabobo.

 

 

03 Idanwo

Gbogbo awọn idanwo ni a ṣe ni ibamu si IEEE C57.12.90-2021, ipin ibora, awọn adanu, impedance, polarity, dielectric, ati lilẹ. Awọn abajade idanwo ni pipe ni ibamu pẹlu awọn iye iṣeduro: Iyapa ipin lori titẹ ni akọkọ jẹ -0.08% si -0.07% (Kere tabi dọgba si 0.5% itẹwọgba); impedance wọn jẹ 5.78% (ifarada ± 7.5%); pipadanu fifuye ni iwọn 85 jẹ 9.836 kW; lapapọ isonu ni 11.231 kW. Ni pataki julọ, ẹrọ iyipada n ṣaṣeyọri99,52% ṣiṣe– Ju awọn ibeere boṣewa DOE 2016 ti 99.48%, ni aṣeyọri pade ibi-afẹde ṣiṣe agbara iṣẹ akanṣe naa. Gbogbo foliteji ti a lo, foliteji ti a fa, idabobo idabobo, ati awọn idanwo jo kọja lori igbiyanju akọkọ laisi eyikeyi didenukole tabi jijo. Imudaniloju didara jẹ atilẹyin nipasẹ ISO/IEC 17025 yàrá ti a fọwọsi, ohun elo iṣatunṣe deede, ati gbigbasilẹ data adaṣe. Awọn ifojusi iṣelọpọ: idanwo ilana ṣiṣe ni kikun, titete boṣewa ẹni-kẹta, ṣiṣe wọn dara ju DOE lọ.

transformer mounting pad test according to IEEE C57.12.90-2021
transformer mounting pad testing

 

 

04 Iṣakojọpọ ati Sowo

4.1 Iṣakojọpọ

Iṣakojọpọ nlo apẹrẹ irin-igi ti a fikun ti o dara fun ilẹ okeere tabi okeere. Oluyipada naa jẹ gbigbe pẹlu nitrogen tabi epo FR3 inu lati ṣe idiwọ gbigba ọrinrin. Iṣakojọpọ ni ibamu pẹlu IEC 60076-10 ati awọn pato okeere alabara. Ṣaaju iṣakojọpọ, ṣayẹwo iṣotitọ ikẹhin ati idanwo idaduro titẹ ni a ṣe lati rii daju pe ko si eewu jijo. Desiccant ati ọriniinitutu awọn kaadi itọkasi wa ninu fun afikun igbẹkẹle lakoko gbigbe. Idaniloju didara pẹlu ayewo wiwo ikẹhin ati atokọ ẹya ẹrọ, pẹlu awọn iwe afọwọkọ ede meji ati awọn ijabọ idanwo. Awọn ifojusi iṣelọpọ: imuduro irin-igi, aabo nitrogen/epo ti o kun, gbigbọn ati apẹrẹ ọrinrin.

 

4.2 Gbigbe

Ṣaaju ki o to sowo, awọn iwọn ita ati iwuwo jẹ timo lodi si iyaworan ikẹhin lati baamu awọn apoti boṣewa tabi awọn ọkọ nla alapin, ni ibamu ni kikun ero eekaderi. Gbigbe ni ibamu pẹlu awọn ilana awọn ẹru elewu omi okun kariaye (ti o ba wulo) ati awọn ibeere iwe aṣẹ aṣa alabara. Ṣiṣayẹwo irisi ikẹhin ati kika ẹya ẹrọ ni a ṣe, pẹlu ijabọ idanwo pipe, fọto orukọ, ati afọwọṣe itọnisọna. Igbẹkẹle gbigbe jẹ idaniloju nipasẹ awọn alabaṣepọ eekaderi ẹrọ iyipada ti o wuwo, pẹlu ipasẹ GPS ati iṣeduro irekọja ni kikun. Awọn ifojusi iṣelọpọ: iriri amọja eru-eru, wiwa kakiri ni kikun, package iwe-ipamọ pipe.

 