2000 KVA Delta Wye Amunawa Ilẹ-34.5 / 0.48 KV|AMẸRIKA 2026
Agbara: 2000 kVA
Foliteji: 34.5D-0.48Y / 0.277 kV
ẹya: pẹlu arrester
Jiangshan Scotech Electrical Co., Ltd jẹ ọkan ninu awọn olupese ti o gbẹkẹle julọ ati awọn olupese ti 2000 kva delta wye transformer grounding-34.5/0.48 kv|USA 2026 ni China. Jọwọ lero ọfẹ lati ra awọn ọja to munadoko fun tita nibi ati gba awọn aworan atọka lati ile-iṣẹ wa. Kan si wa fun alaye sii.

Agbara nibiti o nilo rẹ, ailewu nibiti o ṣe pataki - yan oluyipada paadi ti a gbe sori ẹrọ.
01 Gbogbogbo
1.1 Project Apejuwe
2000 kVA mẹta alakoso pad agesin transformer ti a jišẹ si USA ni 2025. Awọn won won agbara ti awọn transformer jẹ 2000 kVA pẹlu KNAN itutu. Iwọn giga jẹ 34.5D kV pẹlu ± 2 * 2.5% ibiti o tẹ ni kia kia (NLTC), foliteji kekere jẹ 0.48Y / 0.277 kV, wọn ṣẹda ẹgbẹ fekito ti Dyn1.
Oluyipada paadi yii jẹ idi ti a ṣe fun igbẹkẹle, pinpin agbara ṣiṣe giga ni ibugbe, iṣowo, ati awọn agbegbe ile-iṣẹ ina. O kun pẹlu epo ester adayeba FR3 - biodegradable kan, omi sooro ina ti o fa igbesi aye idabobo ni pataki ati dinku eewu ayika ni akawe si epo nkan ti o wa ni erupe ile aṣa. Ẹka naa ni ibamu pẹlu awọn iṣedede ṣiṣe DOE (Ẹka Agbara AMẸRIKA), aridaju iwọn mojuto ati awọn adanu bàbà fun agbara kekere ati awọn ifowopamọ idiyele igba pipẹ. Pẹlu ikọlu ipin ti 5.75%, o funni ni ilana foliteji iduroṣinṣin ati aropin lọwọlọwọ ti o munadoko, imudara aabo eto gbogbogbo. Ijade ẹgbẹ foliteji kekere jẹ irọrun ifopinsi USB ati dẹrọ iwapọ, fifi sori ipele ipele ilẹ, lakoko ti imudani gbaradi ti a ṣe pese aabo to lagbara lodi si monomono ati awọn iwọn apọju. Apade naa ti pari pẹlu awọ funfun ti a bo lulú (RAL 9003), ti o funni ni resistance oju ojo ti o dara julọ, aabo ipata, ati mimọ, irisi profaili kekere ti o ni ibamu pẹlu awọn ilu ilu ode oni ati awọn agbegbe igberiko.
1.2 Imọ Specification
2000 kVA paadi agesin transformer ni pato iru ati data dì
|
Jišẹ si
USA
|
|
Odun
2025
|
|
Iru
Paadi agesin transformer
|
|
Standard
IEEE Std C57.12.34-2022
Ọdun 2016
|
|
Ti won won Agbara
2000 kVA
|
|
Igbohunsafẹfẹ
60HZ
|
|
Ipele
3
|
|
Ifunni
Loop
|
|
Iwaju
Òkú
|
|
Itutu agbaiye
KNAN
|
|
Primary Foliteji
34.5D kV
|
|
Secondary Foliteji
0.48Y/0.277 kV
|
|
Ohun elo Yiyi
Aluminiomu
|
|
Ẹgbẹ Vector
Dyn1
|
|
Ipalara
5.75%
|
|
Iṣẹ ṣiṣe
99.51%
|
|
Tẹ Ayipada
NLTC
|
|
Ibiti titẹ ni kia kia
±2*2.5%
|
|
Ko si Ipadanu Ẹru
1,95 kW
|
|
Lori Ipadanu Fifuye
13.15 kW
|
02 iṣelọpọ
2.1 mojuto

A ṣe ipilẹ mojuto lati ipele giga, ti yiyi tutu ti ọkà Oorun ohun alumọni irin ni apẹrẹ tolera ẹsẹ mẹta. O ṣaṣeyọri pipadanu fifuye ti 1.899 kW nikan ati lọwọlọwọ itara ti 0.17% ni iwọn 20 ati foliteji ti 100%, ti n ṣe afihan ṣiṣe oofa to dara julọ ati ibamu pẹlu awọn iṣedede DOE 2016.
2.2 Yiyi
Oluyipada naa nlo awọn iyipo aluminiomu ni iṣeto ni iyipo Dyn1 meji, pẹlu ± 2 × 2.5% pipa awọn ipese tẹ ni kia kia Circuit ni ẹgbẹ foliteji giga. Ni iwọn 85, awọn adanu fifuye ṣe iwọn 12.677 kW ati ikọlu kukuru kukuru jẹ 5.90%, ti nso ṣiṣe lapapọ ti 99.53%. Awọn windings ti wa ni impregnated pẹlu FR3 adayeba ester ito, eyi ti o fa aye idabobo ati ki o mu ina aabo.

2.3 Low Foliteji Side Jade

Lati dẹrọ asopọ taara si awọn nẹtiwọọki okun ipamo, oluyipada naa ṣe apẹrẹ apẹrẹ ijade ẹgbẹ foliteji kekere. Awọn bushings LV (alakoso mẹta + didoju kan) ni a gbe sori ẹgbẹ ti ojò, gbigba iwapọ, fifi sori ipele ilẹ laisi awọn laini oke. Awọn ebute spade simplify USB lug asomọ ati ki o din oko laala akoko. Bushing didoju (X0) ti wa ni okun taara si paadi ilẹ, pese ọna ikọlu kekere fun awọn ṣiṣan didoju eto. Eto ijade ẹgbẹ yii kii ṣe imudara ẹwa ni ibugbe ati awọn agbegbe iṣowo ṣugbọn tun mu iraye si fun ayewo igbagbogbo ati itọju.
2.4 gbaradi Arrester
Ọkọọkan ninu awọn atọkun foliteji giga giga 200A mẹfa ti ni ipese pẹlu imudani iruju iru igbonwo (imọ-ẹrọ MOV) ni ibamu si ANSI/IEEE C62.11. Awọn imuni wọnyi n pese aabo okeerẹ lodi si awọn ikọlu monomono ati yiyipada awọn iwọn apọju, diwọn awọn foliteji igba diẹ si awọn ipele ailewu ati titọju iduroṣinṣin ti oluyipada ati ohun elo isalẹ. Foliteji ṣiṣiṣẹ lemọlemọfún ti imuni ati isunjade lọwọlọwọ ni a yan ni pẹkipẹki fun eto 34.5 kV, ni idaniloju awọn ewadun ti iṣẹ igbẹkẹle. Olori ilẹ jẹ adaorin bàbà ti o rọ ti o dari agbara gbaradi si ilẹ lailewu.
2.5 Ejò Grounding Busbar
Ailewu ati iduroṣinṣin eto ni a fikun nipasẹ eto ilẹ-ilẹ meji nipa lilo awọn ohun elo idẹ ti o ga. Awọn paadi ilẹ irin alagbara meji ti ko ni awọ - ọkan ninu yara HV ati ọkan ninu yara LV - ẹya kọọkan awọn ihò meji fun awọn asopọ ti o ni aabo. Bushing didoju (X0) jẹ asopọ taara si paadi ilẹ LV, ṣiṣẹda didoju to lagbara si mnu ilẹ. Awọn olutọpa ilẹ idẹ jẹ iwọn lati kọja agbegbe apakan agbelebu ti o kere ju ti o nilo nipasẹ koodu Itanna ti Orilẹ-ede, ni idaniloju itusilẹ iyara ti awọn sisanwo ẹbi ati agbara itọkasi iduroṣinṣin labẹ gbogbo awọn ipo iṣẹ. Gbogbo ohun elo ilẹ jẹ sooro ipata ati ipo fun iraye si irọrun lakoko fifi sori ẹrọ ati ijẹrisi igbakọọkan.

03 Idanwo ati Idaniloju Didara
Gbogbo transformer faragba akojọpọ awọn idanwo igbagbogbo ni ibamu pẹlu IEEE C57.12.00 2021 ati IEEE C57.12.90 2021, ti a ṣe ni ile-iyẹwu ISO ti a fọwọsi. Eto idanwo naa pẹlu:
• Awọn wiwọn Resistance DC - o pọju awọn iwọn aiṣedeede ti 0.08% (HV) ati 4.78% (LV), daradara laarin awọn ilana gbigba.
Awọn idanwo ipin lori gbogbo awọn ipo tẹ ni kia kia - awọn iyapa lati -0.07% si -0.01%, ti o jinna ni isalẹ ± 0.5% opin.
Idanwo Ibasepo Alakoso – timo Dyn1 fekito ẹgbẹ.
• Ko si Awọn ipadanu Ẹru ati Idunnu lọwọlọwọ - wọn ni 1.899 kW ati 0.17% ni iwọn 20.
• Awọn ipadanu fifuye, Imudaniloju Imudaniloju ati Imudara - ipadanu fifuye 12.677 kW, impedance 5.90%, ṣiṣe 99.53% ni iwọn 85.
• Ohun elo Foliteji Iduro - HV 50 kV / 60 s, LV 10 kV / 60 s - ko si didenukole.
• Induced Voltage Withstand – 2Ur (69.0 kV) ni 150 Hz fun 48 aaya – ko si Collapse.
• Resistance Insulation – awọn iye ti 1.47 GΩ, 1.04 GΩ ati 0.853 GΩ kọja awọn ipo idanwo oriṣiriṣi.
Idanwo jijo – 20 kPa titẹ aimi fun wakati 24 – jijo odo ko si si abuku ayeraye.
Gbogbo awọn abajade ti wa ni igbasilẹ daradara ni ijabọ idanwo ti ifọwọsi, ti fowo si nipasẹ idanwo, oludaniloju ati alakosile, aridaju wiwa ni kikun ati ibamu ilana.


04 Onibara Opin Ipinnu
Lakoko fifi sori aaye kan laipẹ, alabara nilo lati sopọ awọn kebulu 500 kcmil ṣugbọn atilẹba 200 A bushings ko ni ibamu pẹlu awọn asopọ igbonwo ti a beere. Ẹgbẹ imọ-ẹrọ Scotech ni kiakia pese ojutu isọdọtun okeerẹ kan:
• Itọju epo - epo ti a fi omi ṣan si ipele 400 mm ati ki o di ojò lati ṣe idiwọ ọrinrin.
• Rirọpo bushing – gbogbo mefa atilẹba 200 A bushings ti a kuro ati ki o rọpo pẹlu 600 A ese bushings, fa ti abẹnu asiwaju awọn okun 50 100 mm tayọ awọn iwaju kompaktimenti.
• Iṣatunṣe iho Lug – lilo awọn atunṣe ọwọ ọwọ (Φ16) ni awọn igbesẹ ilọsiwaju meji tabi mẹta pẹlu isọdọkan eniyan meji fun ailewu; gbogbo reamed egbegbe won deburred.
• Awọn asopọ iyipada – nibiti reaming ko ṣee ṣe, 3 mm nipọn awọn apẹrẹ iyipada bàbà ni a ṣe ati ti a we pẹlu iwe idabobo 3 mm ni awọn aaye asopọ.
• Atunṣe iṣakoso Torque – Awọn boluti M16 ni 50 55 N·m ati awọn boluti M12 ni 36 45 N·m, pẹlu gbogbo awọn ẹya laaye ti o ya sọtọ nipasẹ 3 mm pressboard ati ni ifipamo pẹlu awọn okun mimu.
• Awọn sọwedowo ifẹhinti lẹhin – ayewo inu inu fun awọn ohun ajeji, atunwo idabobo idabobo, iṣatunkun epo, iṣeto aimi wakati 36, ati ijẹrisi itanna ipari.
Iṣẹ idahun yii ṣe idaniloju akoko idinku kekere ati ṣafihan ifaramo Scotech si didara julọ atilẹyin imọ-ẹrọ.

05 Iṣakojọpọ ati sowo
5.1 Iṣakojọpọ

A ṣe akopọ ẹrọ iyipada ni iṣẹ ti o wuwo, apoti igi ti o yẹ omi okun tabi apoti itẹnu, ti a ṣe apẹrẹ lati koju ẹru nla ati gbigbe gbigbe lori ilẹ. Gbogbo awọn paati ti o jade (awọn bushings, awọn wiwọn, awọn falifu) ti wa ni itọsẹ ọkọọkan pẹlu foomu tabi ipari okuta. Gbogbo awọn ṣiṣi ti wa ni edidi pẹlu fiimu ṣiṣu ati awọn baagi desiccant ti wa ni afikun si iṣakoso ọriniinitutu inu apoti naa. Crate ti wa ni aami kedere pẹlu awọn ilana mimu, iwuwo, ati aarin ti walẹ, irọrun iṣajọpọ ailewu ati gbigbejade. Iyan olona kuro crating wa lati je ki awọn owo sowo fun ọpọ ibere.
5.2 Gbigbe
Oluyipada naa ti wa ni gbigbe bi pipe, ẹyọ ti a pejọ ile-iṣẹ – ti ṣetan fun fifi sori ẹrọ lẹsẹkẹsẹ nigbati o ba de. Sowo boṣewa jẹ nipasẹ ẹru okun lati awọn ebute oko oju omi China pataki (fun apẹẹrẹ, Ningbo tabi Shanghai), pẹlu awọn aṣayan ilẹkun si ẹnu-ọna lori ibeere. Oluyipada gbọdọ wa ni titọ lakoko gbigbe; gbogbo awọn falifu ati awọn ibamu ti wa ni pipade ni aabo. Awọn iwe gbigbe pẹlu iwe-aṣẹ gbigbe, atokọ iṣakojọpọ, risiti iṣowo, awọn ijabọ idanwo, afọwọṣe fifi sori ẹrọ, ati ijẹrisi atilẹyin ọja. Iwapọ paadi ti o gbe ifẹsẹtẹ jẹ ki iṣamulo eiyan ti o munadoko, ati awọn eegun gbigbe ti irẹpọ ati awọn paadi jacking gba laaye fun gbigbe ni irọrun ati gbigbe sori paadi nja ti a pese silẹ.

06 Akopọ
Oluyipada paadi SCOTECH jẹ apere fun awọn nẹtiwọọki pinpin agbara ipamo, awọn agbegbe ibugbe, awọn eka iṣowo, awọn ohun elo ile-iṣẹ, ati awọn iṣẹ agbara isọdọtun gẹgẹbi awọn oko oorun ati awọn ibudo agbara afẹfẹ. Iwapọ rẹ, apẹrẹ profaili kekere ati iṣẹ idakẹjẹ jẹ ki o ni ibamu pipe fun awọn agbegbe ilu nibiti aaye ati ẹwa ṣe pataki.
A fi tọtira gba awọn ibeere, awọn ibẹwo ile-iṣẹ, ati awọn aṣẹ ti a ṣe adani. Awọn ẹgbẹ imọ-ẹrọ ti o ni iriri ati awọn ẹgbẹ tita ti ṣetan lati pese atilẹyin ipari si ipari - lati yiyan ọja ati ijumọsọrọ imọ-ẹrọ si lẹhin iṣẹ tita. Ohunkohun ti iṣẹ akanṣe rẹ nilo, a wa nibi lati ṣafipamọ awọn solusan igbẹkẹle pẹlu iṣẹ-ṣiṣe ati itọju. Kan si wa loni - jẹ ki SCOTECH jẹ alabaṣepọ ti o gbẹkẹle ni pinpin agbara.

Awọn afiwe Gbona: 2000 kva delta wye transformer grounding-34.5 / 0.48 kv|usa 2026, China 2000 kva delta wye transformer grounding-34.5/0.48 kv|usa 2026 olupese, olupese, factory
You Might Also Like
2000 kVA paadi Mount Amunawa-25 / 0,6 kV|Canada 2025
1000 kVA Òkú Iwaju Amunawa-24 / 0,48 kV|AMẸRIKA 2024
1000 kVA paadi Amupada Iye Akojọ-13.8 / 0.415 kV|Ilu...
500 kVA Òkú Iwaju paadi Amunawa Amunawa-24.94 / 0.48...
1500 kVA paadi Amunawa Amunawa Iye-0.6 / 13.8 kV|AMẸ...
500 KVA Green Electric Amunawa Apoti-23.9 / 0.22 KV|...
Fi ibere ranṣẹ