750 KVA Ilẹ Loop Amunawa-24.94 / 0.6 KV|Canada 2026

750 KVA Ilẹ Loop Amunawa-24.94 / 0.6 KV|Canada 2026

Orilẹ-ede: Canada 2026
Agbara: 750 kVA
Foliteji: 24.94 / 0,6 kV
Ẹya ara ẹrọ: pẹlu Kirk bọtini
Fi ibere ranṣẹ

Jiangshan Scotech Electrical Co., Ltd jẹ ọkan ninu awọn olupese ti o gbẹkẹle julọ ati awọn olupese ti 750 kva ground loop transformer-24.94/0.6 kv|Canada 2026 ni China. Jọwọ lero ọfẹ lati ra awọn ọja to munadoko fun tita nibi ati gba awọn aworan atọka lati ile-iṣẹ wa. Kan si wa fun alaye sii.

 

ground loop transformer

Rọrun lati fi sori ẹrọ, lile lati lu - paadi ti a gbe sori ẹrọ iyipada jẹ ki akoj rẹ ṣiṣẹ lailewu ati daradara.

 

 

01 Gbogbogbo

1.1 Project Apejuwe

EyiPaadi -Ayipada ti a gbe sokejẹ apẹrẹ fun wiwa awọn agbegbe ita nibiti igbesẹ ti o gbẹkẹle{0}} pinpin agbara isalẹ ṣe pataki. Profaili rẹ kekere -, apẹrẹ ti o wa ni apakan n gbe taara sori awọn paadi kọnkan, ti o funni ni aye kan- fifipamọ fifi sori ẹrọ laisi afikun awọn apade aabo lakoko ti o n mu iyipada ailewu ṣiṣẹ lati awọn kebulu akọkọ ipamo.

Ifijiṣẹ iwọn ṣiṣe ṣiṣe to dayato ti 99.15%, eyiilẹ lupu transformerṣe idaniloju awọn ipadanu agbara kekere ni iṣẹ ojoojumọ. Iwọn iwọn otutu epo ti o ga pẹlu awọn eto meji ti awọn olubasọrọ nigbagbogbo n ṣe abojuto awọn ipo igbona nigbagbogbo, pese awọn ifihan agbara itaniji / irin-ajo lati dẹrọ itọju idena ati daabobo eto rẹ lati awọn eewu igbona. Ẹyọkan -paati, isocyanate{3}}ọfẹ akiriliki -ti a pari ni Equipment Grey{5}} jẹ boṣewa lori gbogbo awọn oju ita. Ipari yii ti o tọ, UV{7}} ati oju-ọjọ-ipari aabo n pese aabo ipata to dara julọ lakoko imukuro awọn eewu ilera ni igbagbogbo ni nkan ṣe pẹlu awọn eto isocyanate{9}}awọn ilana imularada. Ni afikun, aKirki bọtiniidẹkùn-Ẹ̀rọ dídi kọ́kọ́rọ́ ń fi aṣẹ fún ọ̀sẹ̀ kan pàtó ti àwọn ìṣiṣẹ́, ní ìdánilójú pé ó lè ṣí minisita náà lẹ́yìn tí a bá ti parí ìyapa ti agbára òkè. Iṣiṣe ẹrọ ẹrọ yii n ṣe aabo aabo mejeeji si iraye si laigba aṣẹ ati aabo to dara fun awọn oṣiṣẹ itọju.

 

 

1.2 Key pato

Sipesifikesonu

Apejuwe

Iṣẹ ṣiṣe

99.15%

Abojuto iwọn otutu

Iwọn iwọn otutu epo ti o ga pẹlu awọn olubasọrọ meji (itaniji / irin-ajo)

Aso ode

Ọkan - paati akiriliki, isocyanate{1}}ọfẹ, Ohun elo Grey

Aabo Interlock System

Kọ́kọ́rọ́ Kirki di -kọ́kọ́ dídi

Iṣagbesori Iru

paadi nja{0}}ti a gbe, kekere-apẹrẹ apakan profaili

 

Oluyipada yii nfunni ni akojọpọ ijafafa ti ṣiṣe giga, abojuto oye, oṣiṣẹ{0}aabo idojukọ, ati gigun{1}}itọju pipẹ{2}ti o ṣetan fun iṣẹ ninu eto pinpin rẹ.

 

1.3 Imọ pato

750 kVA ilẹ lupu transformer iru ni pato ati data dì

Jišẹ si
USA
Odun
2025
Iru
Paadi agesin transformer
Standard
CSA C227.4:21
Ti won won Agbara
750 kVA
Igbohunsafẹfẹ
60HZ
Ipele
3
Ifunni
Radial
Iwaju
Òkú
Itutu agbaiye
ONAN
Primary Foliteji
24,94GrdY / 14,4 kV
Secondary Foliteji
0.6Y / 0.347 kV
Ohun elo Yiyi
Ejò
Ẹgbẹ Vector
YNyn0
Ipalara
5.75%
Iṣẹ ṣiṣe
99.15%
Tẹ Ayipada
NLTC
Ibiti titẹ ni kia kia
±2*2.5%
Ko si Ipadanu Ẹru
1,18 kW
Lori Ipadanu Fifuye
9 kW

 

1.3 yiya

750 kVA ilẹ lupu transformer aworan atọka iyaworan ati iwọn.

ground loop transformer diagram ground loop transformer nameplate

 

 

02 iṣelọpọ

2.1 mojuto

ground loop transformer core

A ṣe iṣelọpọ ipilẹ pẹlu lilo giga {{0}Pimeability otutu- ọkà yiyi - silikoni irin ti o da lori (CRGO), pẹlu awọn paramita ti o baamu ni kikun 750kVA, 5.75% impedance, ati 1.18kW ṣe idaniloju pe ko si pipadanu fifuye. Apejọ pataki naa ni iṣakoso ni wiwọ pẹlu awọn ayewo ilana fun awọn burrs ati awọn ela afẹfẹ, ati pe o jẹri nipasẹ idanwo fifuye ko si{10}} pipadanu fifuye ti 1110W (iduro ni isalẹ) ati lọwọlọwọ moriwu ti 0.81%, ti n ṣe afihan iṣẹ ṣiṣe oofa to dara julọ. Apẹrẹ naa ni ibamu pẹlu CSA C227.4-21 fun awọn oluyipada paadi ipele-mẹta, ati awọn abajade idanwo jẹrisi igbẹkẹle rẹ labẹ boṣewa ṣiṣe CSA C802.1. Awọn ifojusi iṣelọpọ pẹlu 100% ayewo inu ilana ti akopọ lamination ati wiwọn ipadanu koko ṣaaju apejọ ikẹhin.

 

2.2 Yiyi

Gbogbo awọn windings jẹ Ejò, pẹlu foliteji laini akọkọ 24.94GrdY/14.4kV, Atẹle 0.6GRDY/0.347kV, ẹgbẹ fekito YNyn0, ati awọn idiyele BIL ti 125kV (HV) ati 30kV (LV), ni ibamu deede awọn pato aṣẹ naa. Iyapa ipin ti a ṣewọn wa laarin -0.07% ati +0.09% (dara julọ ju ± 0.5%), aiṣedeede resistance LV jẹ 3.08% (Kere tabi dọgba si ibeere 3%), ati pe ibatan alakoso jẹ ijẹrisi bi YNyn0, gbogbo rẹ ni ibamu ni kikun pẹlu CSA C227.4‑21. Atunse pipadanu fifuye si iwọn 85 jẹ 8501W (ifarada +6%), idiwọ kukuru kukuru jẹ 5.96% (ifarada ± 7.5%), ati ṣiṣe jẹ 99.19% (Ti o tobi ju tabi dọgba si 99.15%), n ṣe afihan itanna igbẹkẹle ati apẹrẹ igbona. Didara iṣelọpọ jẹ iṣeduro nipasẹ awọn ẹrọ yikaka CNC pẹlu iṣakoso ẹdọfu, awọn sọwedowo idabobo inter-Tan, ati 100% resistance DC ati awọn idanwo ipin lati yago fun awọn yiyi kuru tabi awọn aṣiṣe onirin.

ground loop transformer winding with 24.94kV voltage

 

2.3 ojò

ground loop transformer tank meeting CSA standards

Ojò jẹ apẹrẹ ti a fi edidi pẹlu ideri didan, ti a ṣe ti irin kekere fun ojò akọkọ ati awọn yara HV/LV, ipade awọn ibeere agbara ẹrọ CSA fun awọn oluyipada omi-omi. Idanwo titẹ titẹ 20kPa fun awọn wakati 12 ko fihan jijo tabi ibajẹ ayeraye; Awọn idanwo epo siwaju sii jẹrisi igbẹkẹle pẹlu akoonu ọrinrin 12.1 mg/kg, ifosiwewe dissipation 0.103%, ati agbara dielectric 65.4 kV. Awọn ifojusi iṣelọpọ pẹlu 100% idanwo titẹ weld (labẹ omi tabi ojutu ọṣẹ), ṣiṣan ṣiṣan epo gbona, ati kikun epo igbale lati rii daju mimọ inu ati iduroṣinṣin idabobo, ni ibamu ni kikun pẹlu awọn ibeere iduroṣinṣin ojò CSA C227.4-21.

 

2.4 ik Apejọ

Apejọ ikẹhin pẹlu awọn asopọ giga-foliteji ti o ya sọtọ (oku-iwaju, kikọ sii radial), awọn ebute spade kekere-simẹnti resin-simẹnti, oluyipada tẹ ni kia kia ko si (± 2× 2.5%), awọn fiusi bayonet mẹta, awọn fiusi ELSP mẹta, ati iyipada fifọ fifuye ipo meji. Ipari ita jẹ apaati ẹyọkan, awọ akiriliki isocyanate-ọfẹ ni Equipment Grey, eyi ti o jẹ ore ayika ati oju ojo-sooro. Awọn pataki pataki:oke epo thermometer pẹlu meji tosaaju ti awọn olubasọrọ(itaniji laiṣe tabi ifihan agbara iwọn otutu latọna jijin), atiEto titiipa bọtini Kirkfun imudara ailewu iṣẹ. Gbogbo awọn asopọ ẹrọ ati itanna jẹ ayẹwo ni ilopo si awọn iyaworan, ati pe apejọ naa ni ibamu pẹlu awọn ibeere CSA C227.4-21 fun awọn ebute, awọn ohun elo ilẹ, ati awọn ami aabo.

ground loop transformer active part

 

 

03 Idanwo

Gbogbo awọn idanwo igbagbogbo ni a ṣe ni ibamu si CSA C227.4-21 ati CSA C802.1-13, wiwọn resistance ibora, ipin, ibatan alakoso, pipadanu fifuye, pipadanu fifuye / ikọlu / ṣiṣe, foliteji ti a lo, foliteji induced, idanwo jo, resistance idabobo, ati awọn idanwo epo. Awọn abajade bọtini: ko si fifuye pipadanu 1110W, pipadanu fifuye 8501W (85 iwọn), ikọlu 5.96%, ṣiṣe 99.19%, ipinya ipin -0.07~{11}}%, idabobo HV&LV si ilẹ 25.0GΩ, epo dielectric agbara, 65.1k ọrinrin epo , 65. ifosiwewe 0.103%, ati itupale gaasi tituka pẹlu apapọ hydrocarbon 0.57μL/L ati C₂H₂=0. Gbogbo awọn idanwo ti kọja laisi didenukole tabi jijo, nfihan agbara itanna ati igbẹkẹle idabobo daradara ju awọn iye iṣeduro lọ.

ground loop transformer routine test are performed according to CSA C227.4‑21 and CSA C802.1‑13
ground loop transformer ratio test

 

 

04 Iṣakojọpọ ati Sowo

4.1 Iṣakojọpọ

Iṣakojọpọ jẹ apẹrẹ fun gbigbe ọja okeere: gbogbo awọn asopọ HV ti o ya sọtọ, awọn ebute LV, mu oluyipada tẹ ni kia kia, ati iwọn ipele epo ti ni aabo pẹlu fiimu isan ti ile-iṣẹ ati awọn bọtini iyasọtọ; Awọn falifu epo ati awọn ebute oko kikun ti wa ni edidi pẹlu awọn pilogi aabo asapo, ati awọn ipo tẹ ni kia kia ti samisi kedere. Oluyipada naa ti wa ni aabo ni aabo si skid onigi ti o wuwo, irin ti a fi agbara mu pẹlu ohun elo timutimu ni ẹgbẹ ati okun irin. Iwọn apapọ ati iwuwo lapapọ tẹle iyaworan naa, ati pe apoti onigi jẹ fumigated/abojuto ooru, ojo ati ẹri ọrinrin, ni idaniloju pe ko si ibajẹ, jijo, tabi ipata lakoko gbigbe ọna jijin ati mimu mimu lọpọlọpọ.

 

4.2 Gbigbe

Oluyipada naa ti wa ni gbigbe sinu apoti cube giga ẹsẹ 40 tabi bi breakbulk, pẹlu ayewo wiwo ikẹhin ati atokọ awọn ẹya ẹrọ (pẹlu thermometer epo, Kirk‑bọtini, orukọ orukọ, ati bẹbẹ lọ) ṣaaju ikojọpọ. O wa ni titọ ati ni aabo daradara lati yago fun ijaya lakoko gbigbe. Gbigbe naa pẹlu ijabọ idanwo ile-iṣẹ pipe, ijẹrisi ti ibamu, fifi sori ẹrọ ati ilana itọju, ati alaye kan ti ibamu boṣewa CSA. Itusilẹ iṣakoso didara ati, ti o ba nilo, iwadii ẹni-kẹta ni a ṣe ṣaaju fifiranṣẹ. Gbogbo awọn iwe aṣẹ ni a fi ranṣẹ pẹlu awọn ẹru lati rii daju gbigba ati gbigba ti o dara ni aaye alabara.

 

 

05 Akopọ

Ni akojọpọ, transformer loop ilẹ 750kVA ni kikun baamu awọn aye adehun ni apẹrẹ, iṣelọpọ, idanwo, iṣakojọpọ ati gbigbe, ati ni ibamu pẹlu CSA C227.4-21 ati CSA C802.1-13. Awọn abajade idanwo bọtini - ipadanu ko si, pipadanu fifuye, ikọlu, ṣiṣe, ati iṣẹ idabobo - jẹ o tayọ, ijẹrisi igbẹkẹle ni kikun. Didara jẹ idaniloju nipasẹ iṣakojọpọ konge mojuto CRGO, Yiyi Ejò CNC, kaakiri epo gbona pẹlu kikun igbale, ati 100% idanwo igbagbogbo. Awọn ifojusi iṣelọpọ pẹlu awọ akiriliki isocyanate-ọfẹ ayika (Equipment Grey), thermometer epo oke kan pẹlu awọn akojọpọ awọn olubasọrọ meji, eto interlock Kirk-key, ati awọn ẹya ẹrọ yiyan. Oluyipada naa pade gbogbo aabo ati awọn ibeere ṣiṣe ni Ariwa Amerika fun awọn ayirapada pinpin paadi ati pe o ti ṣetan fun iṣẹ igbẹkẹle.

ground loop transformer supplier

 

Awọn afiwe Gbona: transformer lupu ilẹ, olupese, olupese, owo, iye owo