25 KVA Nikan polu Amunawa-14.4 / 0.12 * 0,24 KV|Canada 2025

25 KVA Nikan polu Amunawa-14.4 / 0.12 * 0,24 KV|Canada 2025

Orilẹ-ede Ifijiṣẹ: Canada 2025
Agbara: 25kVA
Foliteji: 14.4-0.12 / 0.24kV
Ẹya: Foliteji Meji & Idaabobo IFD
Fi ibere ranṣẹ

Jiangshan Scotech Electrical Co., Ltd jẹ ọkan ninu awọn olupese ti o ni igbẹkẹle julọ ati awọn olupese ti 25 kva ẹyọkan ọpá transformer-14.4/0.12*0.24 kv|Canada 2025 ni China. Jọwọ lero ọfẹ lati ra awọn ọja to munadoko fun tita nibi ati gba awọn aworan atọka lati ile-iṣẹ wa. Kan si wa fun alaye sii.

 

25 kVA single pole transformer

SCOTECH – igbẹkẹle 25 kVA olupilẹṣẹ oluyipada opo kan ati olupese

 

 

01 Gbogbogbo

1.1 Project Apejuwe

25 kVA Nikan-Ayipada Ipele Ipele Ipele lati SCOTECH rọrun lati fi sori ẹrọ lori awọn ọpá ohun elo ori. O jẹ igbẹkẹle gaan ati pe o wa pẹlu awọn ẹya ẹrọ pataki. Ọpá - awọn ẹyọ ti a gbe soke bii eyi dara julọ fun awọn agbegbe igberiko tabi awọn aaye ti o ni awọn laini oke. Wọn rọrun lati fi sori ẹrọ, rọrun lati ṣetọju, ati idiyele{6}} munadoko fun awọn agbegbe iwuwo kekere{{7}.

Oluyipada yii n lọ silẹ giga - ina foliteji (24,940 GRDY/14,400 V) si ibi aabo 120/240 V fun awọn ile ati awọn iṣowo kekere lori awọn nẹtiwọọki 60 Hz. O ni awọn windings aluminiomu ati irin laminated mojuto. Iṣiṣẹ jẹ Ti o tobi ju tabi dọgba si 98.87%, laisi - pipadanu fifuye ti 85 W ati ipadanu ẹru ti 254 W. Iṣeduro rẹ jẹ 1.97% (± 10%), ni idaniloju foliteji iduroṣinṣin labẹ ẹru.

O pẹlu Kii - Oluyipada Iyipada Fifuye (NLTC) pẹlu iwọn titẹ ± 2×2.5% fun atunṣe foliteji. Giga 18kV -olumudani foliteji ṣe aabo fun oluyipada lati inu foliteji ati ina mọnamọna. Ẹka naa nlo itutu agbaiye ONAN ati idabobo epo nkan ti o wa ni erupe ile, pẹlu ojò edidi fun iṣẹ ita gbangba ti o gbẹkẹle. Oluyipada naa nlo itutu agbaiye ONAN ati idabobo epo nkan ti o wa ni erupe ile, pẹlu apẹrẹ ojò ti o ni edidi fun iṣẹ ita gbangba ti o gbẹkẹle. O le ni irọrun gbe sori igi tabi awọn ọpa ohun elo nja, ti o nilo itọju kekere.

Apẹrẹ fun awọn agbegbe ibugbe, awọn oko, ati awọn ohun elo iṣowo kekere, oluyipada yii n pese agbara ti o gbẹkẹle ni igberiko ati awọn nẹtiwọọki pinpin igberiko, awọn amugbooro nẹtiwọọki, ati awọn agbegbe ti o ni itara si awọn iṣẹlẹ jiji tabi awọn iṣẹlẹ ina.

 

 

 

1.2 Imọ pato

25kVA nikan polu transformer sipesifikesonu ati data dì

Jišẹ si
Canada
Odun
2025
Iru
Polu agesin transformer
Standard
CSAC2.2-06 / C802.1-23
Ti won won Agbara
25KVA
Igbohunsafẹfẹ
60HZ
Polarity
Àfikún
Ipele
Nikan
Itutu agbaiye
ONAN
Insulant olomi
Epo Eruku
Primary Foliteji
24940GRDY/14400 V
Secondary Foliteji
120/240 V
Ẹgbẹ Vector
Ii6
Ohun elo Yiyi
Aluminiomu
Ipalara
1.97%(±10%)
Ṣiṣe ati Awọn adanu Standard
Ti o tobi ju tabi dọgba si 98.87%
Tẹ Ayipada
NLTC
Ibiti titẹ ni kia kia
±2*2.5%
Ko si Ipadanu Ẹru
85 W
Ipadanu fifuye ni Foliteji ti a Ti wọn
254 W
Awọn ẹya ẹrọ
18kV HV Arrester

 

1.3 yiya

25kVA iyaworan oluyipada opo kan ati apẹrẹ orukọ

25 kVA single pole transformer drawing 25 kVA single pole transformer nameplate

 

 

02 iṣelọpọ

2.1 mojuto

25 kVA single pole transformer iron core

Ọkàn ọpá kan- transformer tí a gbé ró jẹ́ kókó inú oofa rẹ̀, tí a sábà máa ń fi àwọn ìyẹ̀n irin tín-ínrín ṣe. Ipilẹ ṣe iranlọwọ agbara oofa gbigbe ni irọrun laarin awọn iyipo akọkọ ati Atẹle. Eyi ngbanilaaye oluyipada lati pese foliteji iduroṣinṣin pẹlu pipadanu agbara kekere ati ṣiṣẹ ni igbẹkẹle lojoojumọ.

 

2.2 Yiyi

Awọn oluyipada wọnyi ni bankanje aluminiomu fun kekere{{0} ẹgbẹ foliteji. Okun Ejò ni a lo fun ẹgbẹ giga{2}. Ile-iṣẹ naa nṣiṣẹ awọn ilana meji lọtọ pẹlu awọn ẹrọ iyasọtọ ati oṣiṣẹ oṣiṣẹ. A ṣe idanwo idabobo, iwọn, ati resistance fun gbogbo okun lati rii daju pe ẹyọ kọọkan n ṣiṣẹ bi a ti ṣe apẹrẹ.

25 kVA single pole transformer coil

 

2.3 ojò

25 kVA single pole transformer oil tank

Ara ojò, ideri, ati gbogbo awọn paati welded ita gba itọju ipata - lẹhin alurinmorin lati ṣe deede si ita, ọriniinitutu, eti okun, ati awọn agbegbe miiran ti o ni itara si ipata tabi sokiri iyọ. Ilana yii ṣe idaniloju pe oluyipada le ṣiṣẹ ni iduroṣinṣin fun igba pipẹ, paapaa ni awọn agbegbe ti o ni afẹfẹ okun ti o lagbara ati ọriniinitutu giga.

 

 

03 Idanwo

25 kVA single pole transformer testing-1
25 kVA single pole transformer testing-2

 

 

04 Iṣakojọpọ ati gbigbe

4.1 Iṣakojọpọ

25 kVA single pole transformerpacking-1
25 kVA single pole transformerpacking-2

 

4.2 Gbigbe

25 kVA single pole transformer shipping-1
25 kVA single pole transformer shipping-2

 

 

05 Aabo ati Itọju Awọn ero

25 kVA single pole transformer
 

Paapaa ni awọn agbegbe eti okun lile, ọpa ti a gbe soke{0} awọn transformer jẹ igbẹkẹle, ṣugbọn ayewo igbagbogbo ṣe pataki. Iyọ -afẹfẹ ti o rù, iji ooru, ati yinyin igba otutu le yara ipata tabi ṣẹda wahala ẹrọ. Awọn ewu pataki pẹlu:
• Epo n jo
• Monomono{0}} awọn ikuna ti o fa
• Overloads nigba lojiji eletan spikes
Lati dinku awọn eewu gigun, awọn ohun elo nigbagbogbo gbarale awọn sensọ igbona ati awọn ayewo drone lati ṣe atẹle ipo oluyipada lati ilẹ.

 

Awọn afiwe Gbona: Oluyipada polu kan, olupese, olupese, idiyele, idiyele

Fi ibere ranṣẹ