3150 kVA Amunawa Ni Power System-0,4 / 6,6 kV|South Africa 2025

3150 kVA Amunawa Ni Power System-0,4 / 6,6 kV|South Africa 2025

Orilẹ-ede: South Africa 2025
Agbara: 3150 kVA
Foliteji: 0.4 / 6,6 kV
ẹya: Hot galvanized
Fi ibere ranṣẹ

 

 

3150 kVA transformer in power system

Nsopọ Ọjọ iwaju pẹlu Idurosinsin lọwọlọwọ, Yan Amunawa pinpin fun kikọlu odo!

 

01 Gbogbogbo

1.1 Project abẹlẹ

3150 kVA igbese soke epo immersed pinpin transformer ti a jišẹ si South Africa ni 2025. Awọn won won agbara ti awọn transformer jẹ 3150 kVA pẹlu ONAN itutu. Foliteji akọkọ jẹ 0.4 kV, foliteji keji jẹ 6.6 kV pẹlu ± 2 * 2.5% ibiti o tẹ ni kia kia (NLTC), wọn ṣẹda ẹgbẹ fekito ti Dyn11.

Oluyipada pinpin 3150kVA yii jẹ ipinnu akọkọ fun lilo ninu awọn eto iran agbara oorun fun iyipada daradara ati pinpin agbara itanna. Mejeeji giga{2}}foliteji ati kekere{3} awọn ẹgbẹ foliteji ti ni ipese pẹlu awọn apoti okun ti a yasọtọ fun asopọ okun ailewu ati itọju. Ti ni ipese pẹlu isunmọ gaasi ti o ni ifura ti o ṣe abojuto awọn ipo gaasi inu ti oluyipada ni akoko gidi, ni iyara idamo awọn aṣiṣe inu ati awọn ikuna idabobo. Ni iṣẹlẹ ti iran gaasi aiṣedeede, isọdọtun gaasi yoo ṣiṣẹ ni iyara lati ge ipese agbara kuro, idilọwọ jijẹ ti awọn ijamba. Iwọn iwọn otutu ti o ga julọ- pipe ti wa ni fifi sori ẹrọ lati ṣe atẹle iwọn otutu yiyi ni akoko gidi ati rii daju iṣiṣẹ laarin iwọn otutu to ni aabo. Iwọn iwọn otutu epo ni a pese lati ṣe atẹle iwọn otutu ti epo iyipada, ni idaniloju iṣẹ ṣiṣe itusilẹ ooru to dara ati imunadoko.

 

 

1.2 Imọ pato

3150 kVA igbese soke epo immersed pinpin transformer sipesifikesonu ati data dì

Jišẹ si
gusu Afrika
Odun
2025
Iru
Epo immersed pinpin transformer
Standard
IEC60076
Ti won won Agbara
3150 kVA
Igbohunsafẹfẹ
50 HZ
Ipele
Nikan
Itutu agbaiye
ONAN
Primary Foliteji
0.4 kV
Secondary Foliteji
6.6 kV
Ohun elo Yiyi
Aluminiomu
Ipalara
5.92%
Tẹ Ayipada
NLTC
Ibiti titẹ ni kia kia
±2*2.5%
Ko si Ipadanu Ẹru
2,94 kW
Lori Ipadanu Fifuye
32,8 kW
Awọn ẹya ẹrọ
Standard iṣeto ni
Awọn akiyesi
N/A

 

1.3 Yiya

3150 kVA ṣe igbesẹ epo immersed pinpin awọn iwọn transformer ati awọn alaye iwuwo

3150 kVA step up oil immersed distribution transformer drawing 3150 kVA step up oil immersed distribution transformer nameplate

 

 

02 iṣelọpọ

2.1 mojuto

Apẹrẹ koko ẹsẹ mẹta {{0}Ipasẹ mẹta{1} ni o nmu iyika oofa ṣiṣẹ, ni imudara lilo ti ṣiṣan oofa. Bi abajade, oluyipada le mu awọn ipele agbara ti o ga julọ pẹlu iwọn kekere ati iwuwo, ti n ṣe afihan iwuwo agbara to dayato. Lilo awọn ohun elo ti o ga- ati awọn ilana iṣelọpọ to peye n dinku pupọju hysteresis ati awọn adanu lọwọlọwọ eddy, imudara agbara agbara ti transformer labẹ awọn ipo fifuye, eyiti o ṣe deede pẹlu agbara igbalode- fifipamọ ati awọn ibeere aabo ayika.

three-phase three-leg core design

 

2.2 Yiyi

3150 kVA step up oil immersed distribution transformer foil winding

Awọn kekere foliteji yikaka ojo melo employs a bankanje oniru, lilo tinrin ati jakejado Ejò tabi aluminiomu foils lati dagba ọpọ ni afiwe adaorin ona. Apẹrẹ yii kii ṣe imudara agbara ẹrọ gbogbogbo nikan ṣugbọn o tun ni imunadoko dinku resistance ti yikaka. Foliteji giga jẹ okun waya-egbo ati okun waya tinrin pẹlu itọju idabobo pataki le duro ni foliteji giga laisi didenukole, ni idaniloju aabo ati iṣẹ iduroṣinṣin ti transformer.

 

2.3 ojò

A ti bo ojò pẹlu ipata pataki kan{{0}sooro ati UV{1} Layer sooro lati pade awọn ibeere kan pato ti agbegbe iran agbara oorun, ni idaniloju iṣiṣẹ pipẹ{2} pipẹ rẹ. Apẹrẹ naa ni ibamu pẹlu kilasi aabo IP44 ati loke, ni idilọwọ imunadoko eruku ati iwọle ọrinrin, aabo aabo ohun elo labẹ awọn ipo ita.

3150 kVA step up oil immersed distribution transformer oil tank

 

2.4 ik Apejọ

3150 kVA step up oil immersed distribution transformer  assembly

Apejọ mojuto: Ni aabo pejọ mojuto sori fireemu ipilẹ, ni idaniloju iduroṣinṣin ti Circuit oofa.

Yiyi fifi sori: Fi sori ẹrọ kekere foliteji ati ki o ga foliteji windings ni ọkọọkan, aridaju idabobo ati ailewu ipinya.

Itutu eto iṣeto ni: Fi sori ẹrọ eto itutu agbaiye (ojò epo ati awọn radiators) ati ki o fọwọsi pẹlu epo idabobo lati ṣe iranlọwọ ni itusilẹ ooru.

Itanna Equipment Asopọ: So iṣakoso iṣakoso, relays, ati awọn iyipada, ni idaniloju itọju idabobo to dara.

Apade Apejọ: Fi sori ẹrọ apoti aabo, ipade awọn ibeere kilasi Idaabobo IP lati ṣe idiwọ eruku ati titẹ omi.

 

 

03 Idanwo

1. Idiwọn Idabobo Resistance

2. Ṣayẹwo ti Voltage Ratio ati Vector Group

3. Wiwọn ti Yika Resistance

4. Lọtọ-Agbara Orisun{2}}Imuduro Iduroṣinṣin Foliteji Loorekoore

5. Induced Foliteji withstand Igbeyewo

6. Wiwọn ti Bẹẹkọ

7. Wiwọn ti Impedance Foliteji ati Load adanu

 

3150 kVA step up oil immersed distribution transformer  test
3150 kVA step up oil immersed distribution transformer  testing

 

04 Ojula ati Lakotan

O ṣeun fun kikọ nipa Amunawa Pinpin wa. A ṣe ileri lati pese awọn alabara pẹlu lilo daradara, ailewu, ati awọn solusan agbara igbẹkẹle lati ṣe iranlọwọ fun ọ lati mu pinpin agbara pọ si ati dinku lilo agbara. Boya o wa ni awọn amayederun ilu, iṣelọpọ ile-iṣẹ, tabi awọn ile iṣowo, awọn oluyipada wa le pade awọn iwulo rẹ ati rii daju ipese agbara iduroṣinṣin. Fun alaye diẹ sii tabi awọn ibeere, jọwọ lero ọfẹ lati kan si ẹgbẹ alamọdaju wa. A nireti lati ṣe ifowosowopo pẹlu rẹ lati ṣe igbega ọjọ iwaju alagbero kan!

transformer in power system

 

Awọn afiwe Gbona: paadi transformers, olupese, olupese, owo, iye owo

Fi ibere ranṣẹ