4390 KVA Amunawa-24 / 0.63 KV|Ilu Jamaa ni ọdun 2025
Agbara: 4390 kVA
Foliteji: 23.9GrdY / 13.8-0.63D kV
Ẹya ara ẹrọ: C5M Alatako -Idi ipata

Yan awọn ayirapada ti o gbe paadi fun ṣiṣe, pinpin agbara iwapọ.
01 Gbogbogbo
1.1 Project Apejuwe
4390 kVA meta alakoso pad mounted transformer ti a jišẹ si Jamaica ni 2025. Awọn won won agbara ti awọn transformer jẹ 4390 kVA pẹlu ONAN itutu. Iwọn giga jẹ 23.9GrdY / 13.8 kV pẹlu ± 2 * 2.5% ibiti o tẹ ni kia kia (NLTC), foliteji kekere jẹ 0.63D kV, wọn ṣẹda ẹgbẹ fekito ti YNd1.
Ti a ṣe ẹrọ fun iṣẹ ti o ga julọ ni awọn nẹtiwọọki itanna ode oni, Amunawa Pad Mounted wa n pese igbẹkẹle iyasọtọ ati ṣiṣe. Ẹya ti o logan yii ṣe ẹya mẹta - ipele, mẹta{2}} mojuto ẹsẹ ti iṣapeye fun iṣẹ ṣiṣe 50Hz, ti o ṣaṣeyọri iṣẹ ṣiṣe 99.2% iwunilori pẹlu ikọlu 7.5% fun iṣẹ agbero iduro. Ti o kún fun eco {{7}ore FR3 ito dielectric, o ṣe alekun aabo ina ati igbesi aye iṣẹ ṣiṣe. Lominu ni si apẹrẹ rẹ ni Isọpọ Grounding Shield ati Sleeve Ilẹ iboju Ipinya, eyiti o rii daju aabo ti o pọju nipasẹ kikọlu itanna eletiriki ni imunadoko ati aabo awọn oṣiṣẹ. Ti a gbe sinu apade irin alagbara 304 resilient ti pari ni ipata -sooro, C5M{14}}ẹwu lulú funfun ipele (RAL 9003), ti a ṣe lati farada awọn ipo ayika ti o nbeere julọ.
Pẹlu agbara iṣẹ ṣiṣe ti o lagbara ti 4330kVA ni iwọn 45 ati 4075kVA ni iwọn 50, oluyipada yii duro bi aabo, ti o tọ, ati okuta igun oye fun awọn amayederun pinpin agbara rẹ.
1.2 Imọ pato
4390 kVA paadi agesin transformer ni pato iru ati data dì
|
Jišẹ si
Ilu Jamaica
|
|
Odun
2025
|
|
Iru
Paadi agesin transformer
|
|
Standard
IEC 60076
|
|
Ti won won Agbara
4390 kVA
|
|
Igbohunsafẹfẹ
50HZ
|
|
Ipele
3
|
|
Ifunni
Loop
|
|
Iwaju
Òkú
|
|
Itutu agbaiye
KNAN
|
|
Primary Foliteji
23,9GrdY / 13,8 kV
|
|
Secondary Foliteji
0,69 kV
|
|
Ohun elo Yiyi
Ejò
|
|
Ẹgbẹ Vector
YNd1
|
|
Ipalara
7.5%
|
|
Iṣẹ ṣiṣe
99.2%
|
|
Tẹ Ayipada
NLTC
|
|
Ibiti titẹ ni kia kia
±2*2.5%
|
|
Ko si Ipadanu Ẹru
3.95 kW
|
|
Lori Ipadanu Fifuye
28 kW
|
1.3 Yiya
4390 kVA paadi agesin transformer aworan atọka yiya ati iwọn.
![]() |
![]() |
02 iṣelọpọ
2.1 mojuto

Ipilẹ ẹsẹ mẹta{{0}, ti a ṣe lati inu irin silikoni Ere, jẹ iṣẹ-ṣiṣe fun fifipamọ agbara ti o pọju ati ariwo kekere. O taara awọn owo ina mọnamọna kekere ati iṣẹ idakẹjẹ, ti o jẹ ki o jẹ pipe, aladuugbo{2}} yiyan ọrẹ fun idiyele- munadoko ati pinpin agbara alagbero.
2.2 Yiyi
Gbogbo wa -Eto yiyipo idẹ ṣopọpọ foil HV ati okun waya LV fun ṣiṣe ti o pọ julọ ati aabo ooru. Apẹrẹ ti o ga julọ yii ṣe idaniloju ipadanu agbara kekere, imudara kukuru -agbara iyika, ati igbesi aye transformer ti o gbooro – jiṣẹ iye otitọ nipasẹ awọn idiyele iṣẹ ti o dinku.

2.3 ojò

Ojò irin alagbara 304 wa pẹlu aabo C5M duro awọn agbegbe lile lainidi. Ipari funfun ti o tọ duro jẹ mimọ ati ipata-ọfẹ fun awọn ọdun mẹwa, imukuro awọn idiyele itọju ati idaniloju aibalẹ-iṣẹ ẹri ni awọn agbegbe eti okun tabi awọn agbegbe ile-iṣẹ.
2.4 ik Apejọ
Apejọ ikẹhin wa ṣe idaniloju imuṣiṣẹpọ pipe laarin giga - ṣiṣe to gaju, gbogbo{1}} awọn iyipo idẹ, ati ojò irin alagbara. Ijọpọ pipe yii n pese iṣẹ iṣeduro pẹlu awọn idiyele igbesi aye kekere, pese awọn ọdun ti itọju{3}}ọfẹ.

03 Idanwo
Ti a ṣe deede si awọn iwulo pataki rẹ fun igbẹkẹle, ṣiṣe, ati akoyawo didara, ẹrọ oluyipada mẹta{{0}pase pad ti a gbe sori ẹrọ ni idanwo pipe ti o kọja ibamu ipilẹ. Ni atẹle awọn iṣedede IEC, awọn idanwo bọtini pẹlu awọn sọwedowo idena yiyi to peye (oṣuwọn aiṣedeede ti o pọju 4.59%), ko si - pipadanu iwuwo (3.564kW), iduro dielectric ti o lagbara, ati 24- jijowakati{12}} ijẹrisi. A duro jade nipa jiṣẹ iperegede wiwọn: 99.28% ṣiṣe (kọja 99.2% o kere ju), ibatan alakoso deede (YNd1). A nfunni ni gbangba, data idanwo iṣẹ ṣiṣe ati atilẹyin ibeere kiakia, fifun ọ ni igboya pe ẹrọ oluyipada rẹ jẹ agbara-daradara, ti o tọ, ati atilẹyin nipasẹ olupese ti o ṣe adehun si aṣeyọri iṣẹ ṣiṣe rẹ.
|
Rara. |
Nkan Idanwo |
Ẹyọ |
Gbigba Awọn iye |
Awọn iye Diwọn |
Ipari |
|
1 |
Awọn wiwọn Resistance |
% |
Iwọn aidogba resistance ti o pọju |
4.59 |
Kọja |
|
2 |
Awọn idanwo ipin |
% |
Iyapa ti ipin foliteji lori titẹ ni akọkọ: Kere tabi dọgba si 0.5% Aami asopọ: YNd1 |
-0.05% ~ -0.03% |
Kọja |
|
3 |
ipele{0}}awọn idanwo ibatan |
/ |
YNd1 |
YNd1 |
Kọja |
|
4 |
Ko si - awọn adanu fifuye ati lọwọlọwọ igbadun |
/ |
I0 :: pese iye iwọn |
0.23% |
Kọja |
|
P0: pese iye iwọn |
3.564kW |
||||
|
Ifarada fun ko si pipadanu ẹru jẹ +15% |
/ |
||||
|
5 |
Fifuye adanu impedance foliteji ati ṣiṣe |
/ |
t:75 iwọn ifarada fun ikọjujasi jẹ ± 10% ifarada fun pipadanu fifuye lapapọ jẹ +10% |
/ |
Kọja |
|
Z%: iye iwọn |
7.06% |
||||
|
Pk: iye iwọn |
28.162kW |
||||
|
Pt: iye iwọn |
31.726kW |
||||
|
Ṣiṣe ko kere ju 99.2% |
99.28% |
||||
|
6 |
Applied Foliteji Igbeyewo |
kV |
LV/: 10kV 60s |
Ko si iparun ti foliteji idanwo waye |
Kọja |
|
7 |
Induced Foliteji withstand Igbeyewo |
kV |
Foliteji ti a lo (KV):2Ur |
Ko si iparun ti foliteji idanwo waye |
Kọja |
|
Iye akoko:40 |
|||||
|
Igbohunsafẹfẹ (HZ): 150 |
|||||
|
8 |
Idanwo jijo |
kPa |
Ipa titẹ: 50kPA |
Ko si jijo ati ki o ko Bibajẹ |
Kọja |
|
Iye akoko: 24h |
|||||
|
9 |
Idiwon Resistance idabobo |
GΩ |
HV{0}LV si Ilẹ |
1.87 |
/ |
|
LV-HV si Ilẹ |
1.15 |
||||
|
HV&LV si Ilẹ |
0.832 |


04 Iṣakojọpọ ati Sowo
4.1 Iṣakojọpọ

A máa ń kó gbogbo ẹ̀ka ọ́fíìsì ránṣẹ́ sí - àwọn àpótí onígi tí wọ́n kọ́, tí a ṣe fún ìdáàbòbò tó pọ̀ jù lọ lákòókò ìrìnàjò. Iṣakojọpọ ti o lagbara yii ṣe idaniloju pe ẹrọ oluyipada rẹ de si aaye ni pipe, ti ṣetan{2}lati fi sori ẹrọ{3}, imukuro awọn ewu inawo ati awọn idaduro iṣẹ akanṣe ti o ni ibatan pẹlu ibajẹ gbigbe.
4.2 Gbigbe
A ni oye lati ṣakoso gbogbo ẹwọn irinna DDU ti mẹta rẹ-paadi ipele{1} ti a gbe soke si PAC Kingston Papa ọkọ ofurufu Ltd. (KIN). Ilana ti o ni itara wa, lati inu apoti pataki onigi {{4}Crate ti o kọja awọn iṣedede ile-iṣẹ si lilọ kiri awọn ilana ẹru KIN kan pato ati awọn aṣa eletiriki 24/7, ṣe idaniloju dukia pataki rẹ de lailewu ati ni iṣeto. Ailopin, wahala - Ifijiṣẹ ọfẹ si opin irin ajo rẹ n dinku awọn eewu ti ibajẹ ati awọn idaduro iṣẹ akanṣe, pese fun ọ ni ifọkanbalẹ pipe ti ọkan.

05 Ojula ati Lakotan
Nigbati aṣeyọri iṣẹ akanṣe rẹ da lori ipese agbara ti ko yipada ati lori - ifijiṣẹ iṣeto, o nilo idaniloju ninu ohun elo rẹ ati olupese rẹ. Awọn oluyipada paadi ti o wa ni ipele mẹta - ni a ṣe apẹrẹ fun deede pe{3}} n pese igbẹkẹle ti ko baramu lati jẹ ki awọn iṣẹ ṣiṣe rẹ ṣiṣẹ. Ṣugbọn anfani wa lọ siwaju: o jẹ ifaramo wa si Ago rẹ. Pẹ̀lú àdánwò ìfijíṣẹ́ tó le- àti ẹ̀rọ ìpèsè àgbáyé kan tó ṣàn, a rí i dájú pé ẹ̀rọ àyípadà rẹ dé ojúlé gẹ́gẹ́ bí a ti ṣèlérí, ó ti múra sílẹ̀ fún wàhálà{7}}ọ̀fẹ́. Ma ṣe jẹ ki awọn eewu iṣẹ tabi awọn idaduro ṣe iparun iṣẹ akanṣe rẹ. Yan igbẹkẹle ti o wa pẹlu igbasilẹ orin ti a fihan ati pato ẹrọ iyipada ti o gbẹkẹle nipasẹ awọn ohun elo ati awọn ile-iṣẹ ni kariaye.

Awọn afiwe Gbona: 4390 kva transformer, olupese, olupese, owo, iye owo
You Might Also Like
75 kVA 3 Alakoso Pipin Amunawa-13.8 / 0.208 kV|Canad...