50 kVA Amunawa IwUlO polu-13.8 / 0,24 kV|Guyana 2025
Agbara: 50kVA
Foliteji: 13.8kV-240/120V
ẹya: Ejò yikaka

01 Gbogbogbo
1.1 Project abẹlẹ
Ni 2025, a fi awọn ẹya 36 ti 50 kVA ẹyọkan -pase opo-awọn oluyipada si ọdọ alabara igba pipẹ{{5} ni Guyana, ni atẹle ilana ipilẹṣẹ aṣeyọri ti awoṣe kanna ni ọdun 2024. Ti a ṣe si IEEE ati ANSI C57.12.00, awọn ipele IEEE ati ANSI C57.12.00, foliteji kọọkan ti awọn iṣedede V01, foliteji akọkọ ti V013 120/240 V, polarity iyokuro, ati ẹgbẹ fekito Ii0. Ti a ṣe apẹrẹ pẹlu awọn yiyi bàbà, awọn ẹyọ naa funni ni ikọlu 2%, ati pe ko si -ayipada titẹ fifuye (NLTC) pẹlu iwọn atunṣe ± 2×2.5% (10% lapapọ). Ipadanu - ko si ni oṣuwọn ni 160 W, ati pipadanu ẹru naa ni 512 W, ni idaniloju iṣẹ ṣiṣe ti o gbẹkẹle fun awọn ohun elo pinpin iwulo.
Aṣẹ yii kii ṣe idaniloju igbẹkẹle alabara wa ni imọ-ẹrọ imọ-ẹrọ ati iduroṣinṣin ọja ṣugbọn tun mu wiwa wa lagbara ni eka IwUlO Guyanese. Ifijiṣẹ aṣeyọri ti awọn ẹya wọnyi ṣe atilẹyin idagbasoke awọn amayederun agbegbe ati imudara igberiko ati awọn nẹtiwọọki pinpin agbara ilu nipasẹ imuṣiṣẹ ti awọn solusan ọpa ohun elo oluyipada ti o gbẹkẹle.
1.2 Imọ pato
50kVA nikan ipele IwUlO polu agesin transformer sipesifikesonu ati data dì
|
Jišẹ si
Guyana
|
|
Odun
2025
|
|
Iru
Nikan alakoso polu agesin transformer
|
|
Standard
IEEE & ANSI C57.12.00
|
|
Ti won won Agbara
50 kVA
|
|
Igbohunsafẹfẹ
60HZ
|
|
Polarity
Iyokuro
|
|
Ẹgbẹ Vector
Ii0
|
|
Primary Foliteji
13800 V
|
|
Secondary Foliteji
120/240 V
|
|
Ohun elo Yiyi
Idẹ
|
|
Ipalara
2%
|
|
Ọna Itutu
ONAN
|
|
Tẹ Ayipada
NLTC
|
|
Ibiti titẹ ni kia kia
±2X2.5%(Apapọ ibiti=10%)
|
|
Ko si Ipadanu Ẹru
160 W
|
|
Lori Ipadanu Fifuye
512 W
|
|
Awọn ẹya ẹrọ
Standard iṣeto ni
|
1.3 Yiya
50kVA nikan ipele IwUlO polu agesin transformer mefa ati iwuwo awọn alaye

02 iṣelọpọ
2.1 Oofa mojuto
Ọgbẹ mojuto, ṣe pẹlu ni kikun aládàáṣiṣẹ lemọlemọfún lara; ntọju awọn iyapa kekere, aṣọ iṣẹ oofa. Iwapọ, ina to jo, ni ibamu si ọpá{1} awọn iṣeto ti a gbe soke; agbara ẹrọ duro ṣinṣin, iduroṣinṣin labẹ gbigbọn tabi awọn iyipada fifuye. Ṣe idaniloju pe ẹrọ iyipada nṣiṣẹ ni igbẹkẹle, pipẹ -.

2.2 Amunawa Windings

Windings tẹle IEEE ati awọn alaye lẹkunrẹrẹ ANSI; giga -foliteji nlo bankanje bàbà{1}}pinpin aaye ina eletiriki to dara julọ, kekere-foliteji okun waya idẹ, ti o lagbara si awọn ọna kukuru{3}. Automation ntọju coils ni ibamu; igbẹkẹle didara, iṣẹ asọtẹlẹ. Ipele kọọkan ti a ṣayẹwo, ni ibamu, ṣetan fun kikun epo.
2.3 Amunawa ojò
Ojò irin ìwọnba, edidi ati jo{0}} ni idanwo; lagbara to fun mọnamọna, gbigbe gbigbọn. Awọn radiators corrugated ni ẹgbẹ mejeeji, ṣe iranlọwọ lati yọ ooru kuro daradara; ntọju transformer dara labẹ eru eru tabi ga ibaramu otutu. Dabobo mojuto, windings, ìwò išẹ duro dada, ailewu.

2.4 Ik fifi sori & ayewo

Mojuto ati windings ni ibi, epo kun fun idabobo ati itutu; HV/LV bushings, titẹ iderun àtọwọdá, tẹ ni kia kia changer, grounding ebute, radiators fi sori ẹrọ tókàn. Ode ti mọtoto, awọn aṣọ ti a ṣayẹwo; awọn akole, data awo orukọ, awọn aworan onirin jẹri{1}ohun gbogbo ti a ṣayẹwo ṣaaju ifijiṣẹ, ṣetan fun iṣẹ.
03 Idanwo

Idanwo baraku
1. Resistance wiwọn
2. Awọn idanwo ipin
3. Polarity igbeyewo
4. Ko si Awọn ipadanu fifuye ati Ko si fifuye lọwọlọwọ
5. Fifuye adanu ati Impedance Foliteji
6. Applied Foliteji Igbeyewo
7. Induced Foliteji withstand Igbeyewo
8. Idiwọn Resistance Insulation
9. Idanwo Dielectric epo
10. Idanwo Leak pẹlu Ipa fun Liquid Immersed Transformers
Igbeyewo Standard
• IEEE C57.12.20-2017
Ipilẹ IEEE fun Ori {{0}Iru Iyipada Pipin 500 kVA ati Kere; Foliteji giga, 34500 V ati Ni isalẹ; Foliteji Kekere, 7970/13 800YV ati Ni isalẹ
• IEEE C57.12.90-2021
IEEE Standard Code fun Liquid - Pipin Immersed, Power, ati Awọn Ayirapada ti n ṣakoso
• CSA C802.1-13 (R2022)
Awọn iye ṣiṣe to kere julọ fun Liquid{0}}Awọn Ayirapada Pipin Pipin
04 Iṣakojọpọ ati Sowo
![]() |
![]() |
05 Ojula ati Lakotan
50 kVA ẹyọkan -ọpa ipele{2}} ti a gbe sori ẹrọ transformer jẹ apẹrẹ fun imugboroosi pinpin agbara ni igberiko ati agbedemeji{3} awọn agbegbe ilu Guyana. O dara ni pataki fun itanna igberiko, awọn iṣagbega ibugbe, ati awọn ẹru iṣowo ina. 2025 alabara tun aṣẹ ti awọn ẹya 36 tẹsiwaju aṣeyọri ti ifijiṣẹ 2024 akọkọ, ti n ṣe afihan igbẹkẹle to lagbara ni didara ati igbẹkẹle awọn ọja wa.
Ti a ṣe ni ibamu pẹlu awọn iṣedede IEEE ati ANSI North America, transformer naa ṣe ẹya apẹrẹ iwapọ ti o dara julọ fun fifi sori ẹrọ oke. O ti ni ibamu daradara si awọn agbegbe ọrinrin ati gbigbona, ti o funni ni itusilẹ ooru to dara julọ ati iṣẹ ṣiṣe edidi lati rii daju pe igbẹkẹle igba pipẹ- iṣẹ ita gbangba. Apẹrẹ ọgbẹ mojuto ṣe imudara agbara ṣiṣe ati agbara ẹrọ, lakoko ti o ti ṣeto awọn iyipo bàbà fun imudara kukuru -idaabobo ayika. Ojò ti a fi edidi pẹlu awọn imooru corrugated ṣe atilẹyin fun gbogbo iṣẹ oju-ọjọ-.
Oluyipada yii jẹ apẹrẹ fun ipese agbara pinpin ati pe o jẹ yiyan pipe fun itẹsiwaju grid ati awọn iṣagbega amayederun ni awọn agbegbe latọna jijin, ti n ṣafihan wiwa dagba wa ni ọja South America.

Awọn afiwe Gbona: ọpá IwUlO transformer, olupese, olupese, owo, iye owo
You Might Also Like
37,5 kVA Ayirapada Lori Tẹlifoonu polu-34.5 / 0.12 *...
25 kVA Electric Pole Transformer-13.8 / 0.12 * 0.24 ...
50 kVA IwUlO polu Ayirapada-34.5 / 0.12 * 0,24 kV|Ca...
150 kVA Pmt Oluyipada-19.92 / 0.24 * 0.12 kV|Canada ...
75 kVA Powerline Amunawa-13.8 / 0,24 kV|Guyana 2025
50 kVA Amunawa Lori Power Pole-7.97 / 0.12 / 0.24 kV...
Fi ibere ranṣẹ