25 KVA Amunawa Lori A polu-44 / 0.347 KV|Canada 2025

25 KVA Amunawa Lori A polu-44 / 0.347 KV|Canada 2025

Orilẹ-ede: Canada 2025
Agbara: 25 kVA
Foliteji: 44/0.347kV
Ẹya ara ẹrọ: pẹlu Non -PCB aami
Fi ibere ranṣẹ

Jiangshan Scotech Electrical Co., Ltd jẹ ọkan ninu awọn olupese ti o gbẹkẹle julọ ati awọn olupese ti 25 kva transformer lori ọpa kan-44/0.347 kv|Canada 2025 ni China. Jọwọ lero ọfẹ lati ra awọn ọja to munadoko fun tita nibi ati gba awọn aworan atọka lati ile-iṣẹ wa. Kan si wa fun alaye sii.

 

transformer on a pole

Agbara Ilọpo ti o ni ṣiṣan: Amunawa ti o wa titi ti ode oni

 

 

01 Gbogbogbo

1.1 Project Apejuwe

25 kVA nikan ipele opo ti a gbe sori ẹrọ ti a fi jiṣẹ si Ilu Kanada ni ọdun 2025. Agbara ti a ṣe iwọn ti transformer jẹ 25 kVA pẹlu itutu ONAN. Iwọn giga giga jẹ 44 kV pẹlu ± 2 * 2.5% ibiti o tẹ ni kia kia (NLTC), foliteji kekere jẹ 0.347 kV, wọn ṣẹda ẹgbẹ fekito ti Ii6.

Ẹka naa jẹ iṣẹ-ṣiṣe lati ṣe igbesẹ daradara foliteji akọkọ lati 44kV si foliteji keji ti 347V, ti o jẹ ki o dara fun fifunni awọn ẹru iṣowo ati ina tabi ṣiṣẹ bi aaye pinpin ni awọn agbegbe ibugbe.

Ẹya bọtini kan ti oluyipada yii jẹ iduroṣinṣin idabobo giga rẹ, ti a ṣe lati koju awọn aapọn itanna to lagbara. Ni ẹgbẹ giga {{1} foliteji, o ti ni ipese pẹlu awọn igi igbo meji ti a ṣe iwọn fun 250kV Basic Impulse Level (BIL), aridaju aabo ti o ga julọ lodi si ikọlu monomono ati yiyi awọn iyipo ti o wọpọ nigbagbogbo pade lori awọn laini oke. Apa kekere - foliteji n ṣe awọn ẹya igbo meji pẹlu iwọn 30kV BIL, ti o ni ibamu pẹlu iwọntunwọnsi 4-iho NEMA paadi. Iwoye ti o wọpọ yii ṣe iṣeduro awọn asopọ ti ko ni ojuuwọn, aabo, ati ifaramọ si isale switchgear, awọn mita, tabi awọn kebulu pinpin keji, fifi sori aaye ṣiṣanwọle ati itọju.

Ti a ṣe pẹlu omi ti o tọ, ojò ti ko ni aabo oju ojo ati ti o kun fun ito dielectric ti o ga julọ, ẹrọ iyipada yii jẹ fun igba pipẹ{1}, itọju{2}}iṣẹ ti o dinku ni awọn agbegbe ita. Ijọpọ rẹ ti iyipada foliteji kongẹ, agbara gbaradi giga, ati Asopọmọra idiwọn jẹ ki o jẹ igbẹkẹle ati ipade pataki ninu awọn amayederun pinpin itanna.

 

 

 

1.2 Imọ pato

25 kVA polu agesin transformer ni pato iru ati data dì

Jišẹ si
Canada
Odun
2025
Iru
Polu agesin transformer
Standard
CSA C2.1
Ti won won Agbara
25 kVA
Igbohunsafẹfẹ
60HZ
Ipele
1
Polarity
Àfikún
Itutu agbaiye
ONAN
Primary Foliteji
44 kV
Secondary Foliteji
0,347 kV
Ohun elo Yiyi
Aluminiomu
Angular nipo
Ii6
Ipalara
2.15%(±10%)
Tẹ Ayipada
N/A
Ko si Ipadanu Ẹru
0,104 kW
Lori Ipadanu Fifuye
0,309 kW

 

1.3 yiya

25 kVA òpó agesin transformer iyaworan ati iwọn.

transformer on a pole diagram transformer on a pole nameplate

 

 

02 iṣelọpọ

2.1 mojuto

transformer on a pole core

Ipilẹ ọgbẹ ti ọpa SCOTECH - awọn oluyipada ti a fi sori jẹ titọ ni pipe nipasẹ yiyi CNC ti nlọsiwaju pẹlu giga -igi tutu{2}} ọkà ti a yiyi -irin silikoni ti o da lori, ti o nfi ọna asopọ mafa ti o ni pipade ti ko ni abawọn. Wahala ti yọkuro ni kikun nipasẹ isunmọ igbale, lakoko ti o ti mu resistance oju ojo pọ si nipasẹ awọn aṣọ idabobo interlayer ati impregnation resini iposii. Ti a ṣe afiwe pẹlu awọn ohun kohun ti aṣa, ko dinku - pipadanu fifuye nipasẹ 30% -50%, dinku ariwo nipasẹ 7{17}}10dB, ṣe alekun agbara ẹrọ nipasẹ 20% ati dinku iwuwo nipasẹ 15%-20%. Apẹrẹ fun awọn ipo iṣẹ ti ita gbangba ti o wa lati iwọn -40 si iwọn +60, o ṣaṣeyọri iṣẹ ṣiṣe ti ko ni itọju ati igbẹkẹle giga, ni pipe ni pipe awọn iwulo igbega agbara-fifipamọ awọn aini awọn nẹtiwọọki pinpin.

 

2.2 Yiyi

Coils ti SCOTECH ọpá - awọn transformers ti a fi sori ẹrọ ṣe ẹya ilana iṣojuuwọn kan, pẹlu awọn olutọpa ti giga{1}} oxygen mimọ{2}}ọfẹ bàbà alloy ati oju ojo meji{3}} idabobo (Nomex paper + asọ gilasi epoxy). Yiyi ti CNC siwa ati igbagbogbo -iwosan iposii ẹdọfu n ṣe alekun kukuru{7}}idaduro ayika nipasẹ 25%, pẹlu itusilẹ apa Kere tabi dọgba si 5pC. Awọn adanu ti ge nipasẹ 18% -25%, o duro -40 iwọn ~+155 ìyí, koju ọrinrin/iyọ, o si mu iṣẹ ṣiṣe itọju ọdun 20 ṣiṣẹ fun awọn ebute nẹtiwọki pinpin.

transformer on a pole winding

 

2.3 ik Apejọ

transformer on a pole filling oil

Ọpá SCOTECH{0}} awọn oluyipada ti a gbe sori gba ilana apejọ modular kan pẹlu iṣọpọ gaan, awọn ṣiṣan iṣẹ koko ti iṣakoso ni deede. Kokoro ọgbẹ ati awọn coils concentric ti wa ni iṣaju{2}} ti a ṣajọpọ sinu apejọ pataki kan, atẹle nipa gbigbe igbale fun yiyọ ọrinrin kuro. Lẹhinna o jẹ ibaramu ni deede pẹlu ojò aṣa kan ati ki o fi edidi hermetically nipasẹ wiwa jijo helium mass spectrometry. Nkun epo igbale ti o tẹle ati sisọdede rii daju pe epo ti o dara julọ-iṣe idabobo ibọmi.

 

2.4 HV Bushing

Ọpá SCOTECH - ti a fi sori ẹrọ HV bushing transformer: 34.5KV/250A Rating, Ijinna oju-iwe Ti o tobi ju tabi dọgba si 991mm, imun monomono duro 250KV. Ibugbe tanganran pẹlu - idabobo Layer mẹta (Teflon + tube tube + epoxy pipe) inu; tanganran kekere ti a bo pẹlu awọ semikondokito. Ni ipese pẹlu awọn ebute idẹ, atilẹyin PTFE, awọn edidi NBR, ati dimole aluminiomu fun iṣagbesori ojò. Ti di edidi Hermetically ati oju-ọjọ{11}}sooro, ni idaniloju igbẹkẹle ita gbangba giga{12}} idabobo foliteji.

HV bushing

 

2,5 LV Bushing

LV bushing

Ni ibamu pẹlu awọn ilana ANSI{7}}1.2KV/250A fun awọn oluyipada ti a fi sori igi, LV Bushing ni awọn paati bọtini 10: 10 ebute asopọ idẹ, 2 NBR gaskets pẹtẹlẹ, insulator tanganran 1, 1 irin spin- 1 irin spin{13}} nut nut, 1 irin alagbara irin {0} brass flat, washers eso hex idẹ, ati okunrinlada bàbà 1 -pẹlu ojò transformer (ø36.5{21}}R3) ti a yọkuro lati inu iwọn ipese; foliteji ti 30 KV, ati gbigbe agbara-igbohunsafẹfẹ withstand foliteji ti 8 KV, pẹlú pẹlu bọtini iwọn bi t{23}}±0.2, 4-R10, 44.5+0.5, 50.8, 035.31, 047.75, a ojò iho iwọn ti ø36.5, ati aṣamubadọgba- si awọn 1.

 

 

03 Idanwo

Fun igbona LV transformer ti opa, agbara gbigbẹ -igbohunsafẹfẹ ifojusọna foliteji ni a ṣe lati fidi iṣẹ idabobo rẹ labẹ awọn oju iṣẹlẹ iṣẹ ti a ṣe iwọn{1}}ila pẹlu ọpagun ANSI{6}}1.2KV/250A, bushing (ti nfihan aaye oju-iwe ti nrakò ti ko din si K5) foliteji ti ko kere si K2 agbegbe gbigbẹ fun akoko kan pato, ko nilo didenukole, filasi, tabi lọwọlọwọ jijo ajeji lati waye, nitorinaa aridaju igbo le ni igbẹkẹle koju aapọn itanna ati yago fun awọn ikuna idabobo lakoko ohun elo to wulo.

transformer on a pole testing
transformer on a pole test

 

 

04 Iṣakojọpọ ati Sowo

transformer on a pole packing
transformer on a pole shipping

 

 

05 Ojula ati Lakotan

Ni SCOTECH, awọn ayirapada ti a gbe soke ọpa wa jẹ iṣẹ-ṣiṣe lati pade awọn ibeere lile ti pinpin agbara ita gbangba. Ti a ṣe pẹlu awọn gaungaun, oju-ọjọ{1} ikole sooro, iyipada agbara daradara, ati igbẹkẹle igba pipẹ, wọn pese agbara iduroṣinṣin si ibugbe, iṣowo, ati awọn grids igberiko{3} paapaa ni awọn ipo ayika lile. Atilẹyin nipasẹ awọn ọgbọn ọdun wa ti iṣelọpọ transformer, gbogbo ẹyọkan ni idanwo ni lile, atilẹyin nipasẹ awọn iṣẹ imọ-ẹrọ pipe ati lẹhin- itọju tita. Boya o nilo awọn atunto boṣewa tabi awọn solusan ti a ṣe adani, a ti pinnu lati fi agbara awọn iṣẹ akanṣe rẹ pẹlu konge ati iṣẹ ṣiṣe. Kan si ẹgbẹ wa loni lati ṣawari bii awọn ayirapada ti a gbe soke ọpa wa ṣe le mu nẹtiwọki pinpin agbara rẹ pọ si.

transformer on a pole manufacturer

 

Awọn afiwe Gbona: transformer on a polu, olupese, olupese, owo, iye owo

Fi ibere ranṣẹ