75 kVA Amunawa Lori polu-13.8 / 0.347 kV|Canada 2025
Agbara: 75 kVA
Foliteji: 13.8 / 0.347kV
ẹya: pẹlu gbaradi arrester Oga

Pipin Agbara Igbega - Smarter, Yiyara, Awọn Solusan Ti a gbe soke Pole Greener.
01 Gbogbogbo
1.1 Project Apejuwe
A fi jiṣẹ transformer 75 kVA nikan-opa alakoso{2}} si Canada ni ọdun 2025. O ni itutu agbaiye ONAN, foliteji akọkọ ti 13.8 kV pẹlu ±2 × 2.5% ko si-load tap changer (NLTC), ati foliteji keji ti 0.347 kV, ti o ṣe agbekalẹ ẹgbẹ I vei.
Òpó{0}} àwọn transformer tí a gbé sókè bí èyí jẹ́ àwọn èròjà kọ́kọ́rọ́ ti àwọn nẹ́tíwọ́kì pínpín iná. Wọn sọkalẹ ga- ina mọnamọna foliteji si ailewu, awọn ipele lilo fun awọn ile, awọn iṣowo kekere, ati awọn aaye ile-iṣẹ ina. Ti a gbe sori awọn ọpá ohun elo, wọn pese agbara ti o gbẹkẹle- paapaa ni igberiko ati awọn agbegbe igberiko, nibiti awọn laini ipamo ko wulo.
Oluyipada yii jẹ apẹrẹ fun awọn iṣupọ ibugbe, awọn ile itaja kekere, awọn oko, ati awọn ohun elo latọna jijin, gẹgẹbi awọn ibudo ibaraẹnisọrọ tabi awọn aaye iwulo agbegbe. Awọn oke igba akoko, bii ibeere alapapo igba otutu, ati awọn iji lẹẹkọọkan jẹ ki agbara iduroṣinṣin ṣe pataki. Iwapọ rẹ, apẹrẹ ti o lagbara jẹ ki fifi sori taara taara, lakoko ti awọn adanu kekere ati awọn windings aluminiomu ti o tọ tọju itọju iwonba.
Pẹlu idojukọ rẹ lori igbẹkẹle, ailewu, ati ṣiṣe, ẹyọ yii ṣe atilẹyin awọn grids ti ndagba, nfi iduroṣinṣin nẹtiwọọki agbegbe lokun, ati paapaa gba agbara isọdọtun iwọn kekere{{0}. O ṣe apẹrẹ lati fi agbara ti o gbẹkẹle, agbara ailewu -odun{3}} yika, kọja awọn agbegbe oniruuru.
1.2 Imọ pato
75 kVA polu agesin transformer ni pato iru ati data dì
|
Jišẹ si
Canada
|
|
Odun
2025
|
|
Iru
Polu agesin transformer
|
|
Standard
CSA C2.2-06
|
|
Ti won won Agbara
75 kVA
|
|
Igbohunsafẹfẹ
60HZ
|
|
Ipele
1
|
|
Polarity
Àfikún
|
|
Itutu agbaiye
ONAN
|
|
Primary Foliteji
13.8kV
|
|
Secondary Foliteji
0,347 kV
|
|
Ohun elo Yiyi
Aluminiomu
|
|
Angular nipo
Ii6
|
|
Ipalara
2%
|
|
Tẹ Ayipada
NLTC
|
|
Ibiti titẹ ni kia kia
±2*2.5%
|
|
Ko si Ipadanu Ẹru
0.060 kW
|
|
Lori Ipadanu Fifuye
0,810 kW
|
1.3 Yiya
75 kVA òpó agesin transformer iyaworan ati iwọn.
![]() |
![]() |
02 iṣelọpọ
2.1 mojuto
Amorphous alloy core nfun ultra{0}}kekere ko si- pipadanu fifuye (70% kere ju irin silikoni) ati sunmọ{3}} awọn adanu eddy lọwọlọwọ. Ìwọ̀nwọ̀nwọ́n rẹ̀ síbẹ̀síbẹ̀ ọ̀nà ọgbẹ́ tí ó lágbára ní ìdánilójú iṣẹ́ oofa dáradára fún ọ̀pá - àwọn ohun èlò tí a gbé sókè, tí ń pèsè ìmúṣẹ agbára tí kò bára dé ní ìpínkiri agbára.

2.2 Yiyi

Òpó yìí -Típadànù tí a fi ń ṣiṣẹ́ ń lo àpẹrẹ yíyí tí ó dára jùlọ: fọ́ìlì aluminiomu fún ìwọ̀nlẹ̀ -voltage yíyí (iye owó{2}} tó gbéṣẹ́ pẹ̀lú pípàdánù ooru tó dára) àti okun waya bàbà fún fífẹ̀nfẹ́fẹ́ gíga{3} (iṣiṣẹ́-iṣiṣẹ́-inú gíga àti ìfaradà). Iṣeto arabara yii ṣe idaniloju ṣiṣe giga, iduroṣinṣin gbona ati iṣẹ igbẹkẹle ni awọn nẹtiwọọki pinpin.
2.3 ojò
Ojò òpó kan- transformer tí a fi ń ṣe ìpìlẹ̀ jẹ́ ètò dídìdì tí a ṣe ti ipata{1}} àwọn àwo irin tí kò lè fọwọ́ sowọ́ pọ̀, tí a pò mọ́ ọ̀nà onígun tàbí ìrísí onígun, pẹ̀lú ojú rẹ̀ tí a ń tọ́jú pẹ̀lú iyanrìn tí a sì fi àwọ̀ agbógunti- díbàjẹ́ láti lè fara da àwọn ipò tó le níta. Ojò naa kun pẹlu epo idabobo fun itutu agbaiye ati idabobo, ti a ṣe apẹrẹ lati jẹ iwapọ ati iwuwo fẹẹrẹ, ojò naa ti gbe ni aabo lori awọn ọpa ohun elo nipasẹ awọn biraketi welded tabi awọn biraketi.

2.4 ik Apejọ

1. Fifi sori ẹrọ Yiyi:Gbe awọn windings HV/LV sori mojuto, aridaju titete idabobo to dara ati imuduro ẹrọ to ni aabo.
2. Awọn Isopọ Itanna:Sopọ yikaka nyorisi awọn oluyipada tẹ ni kia kia, awọn bushings, ati awọn paati miiran, ijẹrisi resistance olubasọrọ.
3. Kokoro -Gbigbe okun:Gbe apakan ti nṣiṣe lọwọ ti o pejọ sinu adiro gbigbe fun alapapo igbale lati yọ ọrinrin kuro ati rii daju pe idabobo.
4. Gbigbe ojò:Gbe apakan ti nṣiṣe lọwọ ti o gbẹ sinu ojò, lẹhinna ni aabo pẹlu awọn boluti ipilẹ.
5. Fifi sori ẹrọ miiran:Oke titẹ iderun àtọwọdá, OCTC, gbaradi arrester Oga, lilẹ gbogbo awọn isẹpo.
6. Nkún Epo & Ididi:Vacuum-kun epo idabobo si ipele ti a sọ pato, ṣe awọn idanwo iṣapẹẹrẹ epo, ki o si jẹrisi jijo{1}} ni wiwọ lati pari apejọ.
03 Idanwo
|
Rara. |
Nkan Idanwo |
Ẹyọ |
Awọn iye gbigba |
Awọn iye Diwọn |
Ipari |
|
1 |
Awọn wiwọn Resistance |
/ |
/ |
/ |
Kọja |
|
2 |
Awọn idanwo ipin |
/ |
Iyapa ti ipin foliteji lori titẹ ni akọkọ: Kere tabi dọgba si 0.5% Aami asopọ: Ii6 |
-0.03 |
Kọja |
|
3 |
Awọn idanwo polarity |
/ |
Àfikún |
Àfikún |
Kọja |
|
4 |
Ko si - awọn adanu fifuye ati lọwọlọwọ igbadun |
% |
I0 :: pese iye iwọn |
0.33 |
Kọja |
|
kW |
P0Pese iye iwọn (diwọn 85) |
0.048 |
|||
|
(105%)P0Pese iye iwọn (diwọn 85) |
0.058 |
||||
|
/ |
Ifarada fun ko si pipadanu fifuye jẹ ± 10% |
/ |
|||
|
5 |
Awọn adanu fifuye, foliteji ikọlu, awọn adanu lapapọ ati ṣiṣe |
/ |
t:85 iwọn ifarada fun ikọjujasi jẹ ± 15% Ifarada fun pipadanu fifuye lapapọ jẹ ± 6% |
/ |
Kọja |
|
% |
Z%: iye iwọn |
2.03 |
|||
|
kW |
Pk: iye iwọn |
0.740 |
|||
|
kW |
Pt: iye iwọn |
0.791 |
|||
|
% |
Ṣiṣe ko kere ju 98.94% |
99.42 |
|||
|
6 |
Applied Foliteji Igbeyewo |
/ |
LV: 10kV 60s HV: 34kV 60s |
Ko si iparun ti foliteji idanwo waye |
Kọja |
|
7 |
Induced Foliteji withstand Igbeyewo |
/ |
Applied foliteji (KV): 0.694 |
Ko si iparun ti foliteji idanwo waye |
Kọja |
|
Iye akoko: 60 |
|||||
|
Igbohunsafẹfẹ (HZ): 120 |
|||||
|
8 |
Idiwon Resistance idabobo |
GΩ |
HV-LV·to·Ilẹ |
120 |
Kọja |
|
LV-HV si Ilẹ |
20.2 |
||||
|
HV&LV si Ilẹ |
20.9 |
||||
|
9 |
Idanwo jijo |
/ |
Ipa titẹ: 20kPA |
Ko si jijo ati ki o ko Bibajẹ |
Kọja |
|
Iye akoko: 12h |
|||||
|
10 |
Idanwo epo |
kV |
Dielectric Agbara |
55.7 |
Kọja |
|
mg/kg |
Ọrinrin akoonu |
9.7 |
|||
|
% |
Okunfa ifasilẹ |
0.00317 |
|||
|
mg/kg |
Furan Analysis |
0.03 |
|||
|
/ |
Gaasi Chromatography Analysis |
/ |


04 Iṣakojọpọ ati Sowo
4.1 Iṣakojọpọ
Òpópópó tí a fi {{0}ígbékalẹ̀ tí a gbé sókè jẹ́ dídi dídí lọ́nà tí ó séwu nínú àpótí onígi líle kan tí a ṣe láti dúró ṣinṣin ti ìrìnnà àti ìmúlò. Apoti onigi ni a ṣe pẹlu igi ti o tọ, ti o nfihan awọn igun ti a fikun ati awọn egbegbe fun aabo ti a ṣafikun. Ninu inu, ẹrọ oluyipada ti wa ni ṣinṣin ni lilo awọn àmúró ati awọn ohun elo imuduro lati ṣe idiwọ gbigbe ati ibajẹ mọnamọna. Ode ti apoti naa ti samisi pẹlu awọn itọnisọna mimu, awọn alaye iwuwo, ati awọn aami itọnisọna lati rii daju awọn eekaderi to dara.

4.2 Gbigbe

Òpó yìí - a máa kó sínú àpótí onígi tí a ṣe àtúnṣe pẹ̀lú àpótí mọnamọna{1}}àti ọrinrin{2}, lẹ́yìn náà a rù sínú ọkọ̀ akẹ́rù kan nípa lílo ọ̀pá ìdarí fún fífi lọ sí èbúté. A o fi ranṣẹ sinu apoti boṣewa 40ft (ọriniinitutu{5} ti a ṣakoso pẹlu awọn apọn) labẹ awọn ofin CIF si Port of Montreal. Nigbati o ba de, a le gbe apoti naa silẹ nipa lilo awọn apọn tabi awọn apọn. Iṣeduro omi ni kikun (iye 110% risiti, Gbogbo Awọn ewu) ni wiwa gbogbo gbigbe titi di ọjọ 14 lẹhin ti o de{10}.
05 Awọn anfani & Awọn aila-nfani ti Ọpá -Awọn Ayirapada ti a gbe soke
Òpópó-apadàmà tí a gbé só jẹ́ olókìkí. Kí nìdí? Igbesi aye iṣẹ gigun, fifi sori ẹrọ rọrun, ati pe wọn kan ṣiṣẹ. Eyi ni ohun ti o jẹ ki wọn ṣe pataki:
Awọn ohun elo to pọ:Awọn ile, awọn ile-iṣẹ iṣowo kekere, paapaa awọn agbegbe jijin{0}awọn transformer wọnyi mu gbogbo rẹ ṣiṣẹ.
Ipese Agbara Rọ:Ẹyọkan-Ijade ipele jẹ boṣewa. Nilo agbara diẹ sii? Darapọ wọn sinu ipele - mẹta. Rọrun.
Iye owo {{0}Mudoko:Din owo ju epo miiran- awọn oluyipada ti a rìbọmi, sibẹ iṣẹ ṣiṣe duro.
Aaye{0}Nfipamọ:Kekere, iwuwo fẹẹrẹ, ti o joko lori ọpa kan- ko si aaye ilẹ ti o ṣòfo.
Imudara Aabo:Ni giga, ti eniyan ati ẹranko ko de ọdọ. Ewu iparun? Isalẹ.
Ti o tọ:Pipade oniru aabo fun epo. Igbesi aye? Nigbagbogbo 30-60 ọdun.
Fifi sori Rọrun:Imọlẹ to fun ọpá kan. Yara lati gbe soke.
Sugbon o ni ko gbogbo pipe.
Ifihan AyikaAfẹfẹ, ojo, awọn ẹranko ti ngun… gbogbo wọn le fa ibajẹ.
Awọn italaya itọju: Ti nkan ba ṣẹ, o nilo lati ṣiṣẹ soke nibẹ. Ko ṣee ṣe{1} ṣugbọn awọn idiyele n lọ soke.

Awọn afiwe Gbona: transformer lori ọpa, olupese, olupese, owo, iye owo
You Might Also Like
15 kVA Pole Amunawa-24.94 / 0.12 * 0.24 kV|Canada 2024
167 kVA Power polu Amunawa-13.8 / 0.347 kV|Canada 2025
100 kVA Amunawa polu Agesin-13.8 / 0,24 kV|Guyana 2025
75 kVA IwUlO Amunawa-24.94 / 0,12 kV|Canada 2025
50 kVA Amunawa Lori Power Pole-7.97 / 0.12 / 0.24 kV...
75 kVA Pole Amunawa Amunawa-7.97 / 0.12 / 0.24 kV|Ca...
Fi ibere ranṣẹ