37,5 kVA ọpá Amunawa-2.4 / 0,12 kV|Canada 2025
Agbara: 37.5 kVA
Foliteji: 2.4-0.12 / 0.24 kV
Ẹya ara ẹrọ: pẹlu pipa-oluyipada tẹ ni kia kia

Gbe Pipadanu, Mu iṣelọpọ pọ si – Awọn Ayirapada ti a gbe soke Ọpá Smart!
01 Gbogbogbo
1.1 Project Apejuwe
37.5 kVA nikan ipele opo ti o gbe transformer ni a fi jiṣẹ si Ilu Kanada ni ọdun 2025. Agbara ti a ṣe iwọn ti transformer jẹ 37.5 kVA pẹlu itutu ONAN. Foliteji akọkọ jẹ 2.4 kV pẹlu ± 2 * 2.5% ibiti o tẹ ni kia kia (NLTC), foliteji keji jẹ 0.12 / 0.24 kV, wọn ṣẹda ẹgbẹ fekito ti Ii6.
Yi 37.5kVA nikan -pase opo - transformer ti a gbe soke jẹ apẹrẹ fun ṣiṣe daradara ati pinpin agbara ni awọn ohun elo ita gbangba, ti o nfihan bushing giga -voltage (HV) ati awọn bushings kekere mẹta pẹlu 4- iho spade - awọn ọna asopọ to ni aabo{9} Ẹgbẹ HV ṣafikun pipa{11}} oluyipada tẹ ni kia kia (± 2.5% iwọn to ṣatunṣe), gbigba ilana foliteji nigbati o ba ni agbara, lakoko ti ọpọlọpọ{14}} iṣeto LV tẹ ni kia kia ṣe atilẹyin pinpin kaakiri. Ti a ṣe pẹlu idabobo ti o lagbara ati iwapọ, ọpá{15}} ọna gbigbe, ẹyọ yii dara julọ fun itanna igberiko, ina ita, ati lilo ile-iṣẹ kekere{17}, n funni ni awọn adanu kekere ati ṣiṣe igbẹkẹle labẹ awọn ipo akoj. Iṣiṣẹ to peye nilo awọn atunṣe tẹ ni kia kia ti agbara ati itọju igbagbogbo ti awọn igbo ati awọn ebute.
1.2 Imọ pato
37,5 kVA polu agesin transformer ni pato iru ati data dì
|
Jišẹ si
Canada
|
|
Odun
2025
|
|
Iru
Polu agesin transformer
|
|
Standard
CSA C2.2-06
|
|
Ti won won Agbara
37,5 kVA
|
|
Igbohunsafẹfẹ
60HZ
|
|
Ipele
1
|
|
Polarity
Àfikún
|
|
Itutu agbaiye
ONAN
|
|
Primary Foliteji
2.4kV
|
|
Secondary Foliteji
0,12 / 0,24 kV
|
|
Ohun elo Yiyi
Aluminiomu
|
|
Angular nipo
Ii6
|
|
Ipalara
2.7%
|
|
Tẹ Ayipada
NLTC
|
|
Ibiti titẹ ni kia kia
±2*2.5%
|
|
Ko si Ipadanu Ẹru
0,078 kW
|
|
Lori Ipadanu Fifuye
0,720 kW
|
|
Iṣẹ ṣiṣe
98.73%
|
1.3 Yiya
37,5 kVA polu agesin transformer aworan atọka yiya ati iwọn.
![]() |
![]() |
02 iṣelọpọ
2.1 mojuto
Ọgbẹ silikoni irin mojuto ni ẹyọkan -pase opo -awọn oluyipada ti a gbe soke nlo - ọkà ipile - irin silikoni ti o ga, ti o nfihan iṣẹda alailẹgbẹ ati aifẹ oofa kekere. Apẹrẹ yii dinku ko si - adanu fifuye ati ariwo iṣẹ lakoko ṣiṣe aṣeyọri ju 98% lọ. Ipilẹ-itumọ - ti o ni ilọsiwaju jẹ ki pinpin ṣiṣan oofa jẹ ki o jẹ apẹrẹ fun ibeere awọn ohun elo pinpin oke.

2.2 Yiyi

Okun transformer ni ẹyọkan -ọpa alakoso- awọn oluyipada ti o wa ni ọpọlọpọ awọn fẹlẹfẹlẹ ti awọn adari idẹ alapin/yika, ti o wa pẹlu awọn ohun elo dielectric giga{2} foliteji (fun apẹẹrẹ, Nomex tabi DMD). Apẹrẹ yii ṣe idaniloju itusilẹ ooru paapaa, rigidigidi ẹrọ giga, ati idiwọ kukuru -, lakoko ti agbara interlayer iṣapeye n dinku ipalọlọ ibaramu.
2.3 ojò
Awọn tanki epo ti a ṣopọ jẹ ti irin ti o tọ, ti a ṣe apẹrẹ lati koju awọn ipo ita gbangba lakoko ti o pese itutu agbaiye ti o munadoko ati idabobo fun awọn paati inu. Awọn ojò ti wa ni kún pẹlu idabobo epo ti o Sin bi mejeeji a coolant ati dielectric alabọde. Iṣagbesori biraketi ti wa ni ese fun ni aabo fifi sori lori IwUlO ọpá.

2.4 ik Apejọ

1. Apejọ Yiyi:Rọra awọn iyipo HV/LV sori mojuto laminated, aridaju titete to dara ati iduroṣinṣin idabobo.
2. Awọn Isopọ Itanna:Sopọ yikaka nyorisi tẹ ni kia kia oluyipada, bushings, ati awọn miiran irinše, ki o si ni aabo ati ki o idabobo awọn isẹpo.
3. Kokoro -Gbigbe okun:Gbe apakan ti nṣiṣe lọwọ ti o pejọ (mojuto + windings) sinu adiro gbigbe fun alapapo igbale lati yọ ọrinrin kuro.
4. Fifi sori ojò:Gbe apakan ti nṣiṣe lọwọ ti o gbẹ sinu ojò, gbe si ni aabo, ati rii daju idabobo to dara lati awọn odi ojò.
5. Iṣagbesori Ẹya ẹrọ:Fi bushings sori ẹrọ, àtọwọdá iderun titẹ ati awọn ẹya ẹrọ miiran, lẹhinna ṣayẹwo fun awọn n jo.
6. Nkún Epo & Ṣiṣeto:Igbale - kun fun epo idabobo, degas, ati gba laaye lati yanju ṣaaju ṣiṣe ayẹwo awọn ipele epo ati agbara dielectric.
03 Idanwo
|
Rara. |
Nkan Idanwo |
Ipari |
|
|
1 |
Awọn wiwọn Resistance |
Kọja |
![]() |
|
2 |
Awọn idanwo ipin |
Kọja |
|
|
3 |
Awọn idanwo polarity |
Kọja |
|
| 4 | Ko si - awọn adanu fifuye ati lọwọlọwọ igbadun |
Kọja |
|
| 5 | Awọn adanu fifuye, foliteji ikọlu, awọn adanu lapapọ ati ṣiṣe |
Kọja |
|
| 6 | Applied Foliteji Igbeyewo |
Kọja |
|
| 7 | Induced Foliteji withstand Igbeyewo |
Kọja |
|
| 8 | Idiwon Resistance idabobo |
Kọja |
|
| 9 | Idanwo jijo |
Kọja |
|
| 10 | Idanwo epo | Kọja |
04 Iṣakojọpọ ati Sowo
4.1 Iṣakojọpọ
Lati rii daju gbigbe gbigbe ati ibi ipamọ to ni aabo, ọpá{0} ti a gbe sori ẹrọ ti wa ni ti kojọpọ sinu awọn apoti onigi ti aṣa. Ẹyọ naa ni a kọkọ sọ di mimọ a si ṣe ayẹwo lati jẹrisi ko si awọn iṣẹku epo tabi ibajẹ, pẹlu awọn ẹya ti o jade (fun apẹẹrẹ, awọn igbo, awọn wiwọn) ti a we sinu foomu tabi ipari ti nkuta, ati gbogbo ara ti o bo pelu ọrinrin - iwe sooro tabi fiimu ṣiṣu. Lẹhinna o ti ni ifipamo sori pallet onigi ti a fikun nipa lilo awọn okun. Crate, ti a ṣe lati inu igi ti o nipọn 15-20mm, ṣe ẹya awọn àmúró inu lati ṣe idiwọ gbigbe, awọn igun ti a fikun pẹlu awọn biraketi irin, ati awọ ti ko ni omi inu. Awọn akole bii “Ẹlẹgẹ,” “Jeki Gbẹ,” ati “Ẹgbe Soke” ni a somọ, lakoko ti atokọ iṣakojọpọ, awọn ijabọ idanwo, ati iwe afọwọkọ ti wa ni edidi ninu apo ti ko ni omi. Lakoko ikojọpọ, awọn okun ati awọn ohun elo imuduro ni a lo lati daabobo lodi si awọn ipaya lakoko gbigbe gigun{11}.

4.2 Gbigbe

Labẹ awọn ofin CIF, ọpa ti a gbe {{0}po awọn transformer yoo gbe lọ si ibudo ti Montreal. Olupese naa ni iduro fun siseto ẹru ọkọ oju omi, ni wiwa gbogbo awọn idiyele pẹlu iṣeduro ati awọn idiyele ẹru titi ti ẹru yoo de ni ibudo ti nlo. Awọn ayirapada gbọdọ wa ni ifipamọ ni aabo ni aabo oju-ọjọ ati mọnamọna{3}} awọn apoti sooro lati koju awọn ipa mimu ti o pọju ati awọn ipo ayika lakoko gbigbe. Awọn iwe aṣẹ ti o tọ, gẹgẹbi iwe-owo gbigbe, risiti iṣowo, ati iwe-ẹri iṣeduro, yoo pese lati rii daju pe idasilẹ awọn aṣa aṣa ni Montreal.
05 Ojula ati Lakotan
Òpópópó {{0} tí a gbé ìpadàpọ̀ mọ́ jẹ́ ojútùú ìgbẹ́kẹ̀lé àti gbígbéṣẹ́ fún pípínpinpin agbára, tí a ṣe láti dojú ìjà kọ àwọn ipò àyíká tí ó le koko nígbà tí ó ń rí i dájú pé ìlànà foliteji dídúró. Pẹlu ikole ti o lagbara, fifi sori irọrun, ati awọn ibeere itọju kekere, o jẹ yiyan pipe fun awọn nẹtiwọọki IwUlO, itanna igberiko, ati awọn ohun elo ile-iṣẹ. Ti a ṣe afẹyinti nipasẹ awọn iṣedede didara to lagbara ati iṣẹ ṣiṣe ti a fihan, awọn oluyipada wa n ṣe jiṣẹ pipẹ{3}}itọju igba pipẹ ati ṣiṣe ṣiṣe. Kan si wa loni lati wa ojutu pinpin agbara pipe fun awọn iwulo rẹ.

Awọn afiwe Gbona: 37.5 kva polu agesin transformer, olupese, olupese, owo, iye owo
You Might Also Like
100 kVA Tẹlifoonu polu Amunawa-34,5 / 0,24 kV|AMẸRIK...
167 kVA Cooper Paadi Amunawa-13.8 / 0.24 kV|Guyana 2024
50 kVA Amunawa IwUlO polu-13.8 / 0,24 kV|Guyana 2025
50 kVA Nikan polu agesin Amunawa-13.8 / 0.347 kV|Can...
75 kVA Amunawa Agbekọja-24.94 / 0.347 kV|Canada 2025
50 kVA Amunawa Lori Power Pole-7.97 / 0.12 / 0.24 kV...
Fi ibere ranṣẹ